Heat Sink; Removing The Heat Sink - Dell XPS 15 9530 Service Manual

Hide thumbs Also See for XPS 15 9530:
Table of Contents

Advertisement

About this task
The following images indicate the location of the right fan and provide a visual representation of the installation procedure.
Steps
1. Slide the right fan below the heat sink and align the screw hole on fan with the screw hole on the palm-rest and keyboard
assembly.
2. Replace the screw (M2x4) that secures the right fan to the system board.
3. Connect the right-fan cable to the system board.
4. Align the screw holes on the I/O-board bracket with the screw holes on the right fan and the system board.
5. Replace the two screws (M2x4) that secure the I/O-board bracket to the right fan and palm-rest and keyboard assembly.
Next steps
1. Install the
base
cover.
2. Follow the procedure in

Heat sink

Removing the heat sink

Prerequisites
1. Follow the procedure in
CAUTION:
For maximum cooling of the processor, do not touch the heat transfer areas on the heat sink. The
oils in your skin can reduce the heat transfer capability of the thermal grease.
NOTE:
The heat sink may become hot during normal operation. Allow sufficient time for the heat sink to cool before you
touch it.
2. Remove the
base
cover.
About this task
The following image indicates the location of the heat sink and provides a visual representation of the removal procedure.
After working inside your
Before working inside your
computer.
computer.
Removing and installing components
29