HOW TO REMOVE COMPONENTS

3.7 BYPASS VALVE

NOTE: : Before removing water inlet connec-
tion, turn off water to the water heater by
closing the shut off valve and drain the heater.
1. Remove user interface from the water heater.
NOTE: To remove the interface , refer to sec-
tion "3.13 Display".
2. Remove water control wiring harness from the con-
trol board (connector "G")
3. Remove the two white Molex connectors located
rear of the user interface.
4. Remove four screws and two flange bracket.
5. Remove water inlet pipe and bypass pipe
73
IKONIC Tankless Water Heater Service Manual
6. Remove fastener to check valve.
NOTE: If for recirculation model, remove quick
fastener connected to water inlet.
7. Remove quick fastener connected to water control
valve.
Bypass Valve