Siemens RUGGEDCOM M2100F Installation Manual page 48

Hide thumbs Also See for RUGGEDCOM M2100F:
Table of Contents

Advertisement

Chapter 6
Certification
HV Impulse
Dielectric Strength
Damped Oscillatory
Magnetic Field
Environmental Type Tests
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60068-21-1
IEC 60068-21-2
Military Standard Tests
Test
MIL-STD-901D
MIL-STD-167-1
MIL-STD-461E
MIL-STD-1399
MIL-STD-810F
MIL-STD-1275B
38
Description
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Enclosure Ports
Description
Cold Temperature
Dry Heat
Humidity (Damp Heat, Cyclic)
Vibration
Shock
Description
Shock (Hard-Mounted)
Vibration
Electromagnetic Interference
Magnetic Field – DC Magnetic Exposure
Low Pressure Altitude Storage, Low
Pressure Altitude Operational, High
Temperature Storage, High Temperature
Operational, Low Temperature
Storage, Low Temperature Operational,
Temperature Shock Storage, Humidity,
Acceleration, Salt Fog and Vibration
Power Quality
Test Levels
1 kV differential mode @ 1 MHz
2.5 kV Common
1 kV differential mode @ 1 MHz
5 kV (Fail-Safe Relay Output)
5 kV
5 kV
2 kV
2 kV
2 kV
100 A/m
Test Ad
-40 °C (-40 °F), 16 Hours
Test Bd
85 °C (185 °F), 16 Hours
Test Db
95% (Non-Condensing),
55 °C (131 °F), 6 Cycles
Test Levels
Grade A, Equipment Class I, Shock Type A Equipment
Type I (4-33 Hz)
CE101, CE102, CS101, CS114, CS115,
CS116, RE101, RE102, RS101, RS103
Section 070, Part 1
Method 500 Series Procedures
Per Standard
EMC and Environmental Type Tests
RUGGEDCOM M2100F
Installation Guide
Test Levels
2g @ 10-150 Hz
30 g @ 11 ms

Advertisement

Table of Contents
loading