Note: Only remove the knock-out that will be connected to the fresh air intake kit.
Using pliers, remove the rectangular knock-out plate (A) located on
the left or right side of the convection air jacket. Choose the side
that is best for your installation.
Then, install the fresh air kit adapter (B) using
4 screws (C). Secure the flexible pipe (E) (not
included) to the adapter (B) using one of the
adjustable pipe clamps (D). The pipe must be
HVAC type, insulated, and must comply with
ULC S110 and/or UL 181, Class 0 or Class
1. Secure the other end of the pipe to the
outside wall termination (F) using the second
adjustable pipe clamp (D). The outside wall
termination (F) must be installed outside of
the building.