General Installation Requirements - Baxi 746 Installer's Manual

Inset live fuel effect gas fire
Table of Contents

Advertisement

Gas
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Inlet Test Pressure (Cold)
Gas Connection
Burner Injector
Pilot & Atmosphere Sensing
Device
Ignition
Aeration
* When converted using Kit 0595221
The appliance data label is located on a plate at the base of the fire. This can be seen by
removing the lower firefront trim.

3. GENERAL INSTALLATION REQUIREMENTS

3.1
The installation must be in accordance with these instructions.
For the user's protection, in the United Kingdom it is the law that all gas appliances are
installed by competent persons in accordance with the current edition of the Gas Safety
(Installation and Use) Regulations. Failure to install the appliance correctly could lead
to prosecution. The Council for the Registration of Gas Installers (CORGI) requires its
members to work to recognised standards.
In the United Kingdom the installation must also be in accordance with:
All the relevant parts of local regulations.
All relevant codes of practice.
The relevant parts of the current editions of the following British Standards: -
BS 715
BS 4543 Part 2 BS 5440 Part 1 BS 5440 Part 2 BS 5871 Part 1
BS 6461 Part 1 BS 6891
In England and Wales, the current edition of the Building Regulations issued by the
Department of the Environment and the Welsh Office
In Scotland, the current edition of the Building Standards (Scotland) Regulations issued
by the Scottish Executive.
In Northern Ireland, the current edition of the Building regulations (Northern Ireland)
INSTALLER GUIDE
6.0kW (20,500Btu/h)
2.3kW (7,850Btu/h)
20.0 ± 1.0mbar (8.0 ± 0.4in
Stereomatic Cat 82 - 069
Copreci Ref. O.D.S
Piezo Electric. Integral with
BS 1251
Natural (G20)
20mbar
w.g.)
8mm pipe
21500/166
Gas Tap
See section 16.1
BS 1289 Part 1 BS EN 1806
Page 5
Propane (G31) *
37mbar
6.1kW (20,800Btu/h)
3.8kW (12,965Btu/h)
37.0 ± 1.0 mbar (14.85 ±
0.4in w.g.)
8mm pipe
Stereomatic Size 128
Copreci Ref. O.D.S
21500/166 Fitted with RBM
180 - 02 injector
Piezo Electric. Integral with
Gas Tap
Non-adjustable