Operation - JUKI MP-G10-NC Technical Manual

Industrial sewing machine attachment
Table of Contents

Advertisement

6. Operation

CAUTION
Assembly of this device is completed, please check your work once again.
Because there is a case to unexpected behavior, please away from the sewing machine when
the power is turned on and the air pressure.
(1) Pull up on the handle of the filter regulator, adjust to 0.4MPa(4kgf/cm
clockwise direction.
(2) Needle Cooler will work on the sewing machine rotation.
(3) Can adjust the flow rate by the speed controller of the finger valve.
(4) So that it is possible to effectively cool the needle, please adjust the direction of the nozzle.
- 9 -
2
) air pressure by turning in a

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp-g20-nc

Table of Contents