Installation & Operation Instructions; Extension Cords; Installation; Before Operating The Air Compressor - Makita MAC3001 Operating Instructions Manual

Portable electric compressor
Table of Contents

Advertisement

Available languages

Available languages

EXTENSION CORDS

The use of extension cords is not recommended.
dedicated circuit. If the use of an extension cord is unavoidable then make
sure your extension cord is in good condition. When using an extension
cord, be sure to use one heavy enough to carry the current your product
will draw. An undersized cord will cause a drop in line voltage resulting in
loss of power and overheating. Table 1 shows the correct size to use
depending on cord length and nameplate amperage rating. If in doubt, use
the next heavier gauge. The smaller the gauge number, the heavier the
cord.
Ampere Rating
More Than
Not More Than
0
6
10
12

INSTALLATION

Proper care, maintenance and lubrication ensure longevity.
compressor should always be level for proper lubrication. Do not ever
tighten foot bolts as excessive vibration may occur. Use only in a clean,
dry, and well-ventilated area. The compressor has heat dissipation fins for
proper cooling. Keep the fins and other parts that collect dust clean. Do
not place rags or other materials on top of the compressor, as this
obstructs cooling and can be a fire hazard.

BEFORE OPERATING THE AIR COMPRESSOR

PLEASE CHECK THE FOLLOWING CAREFULLY:
1) Check to see that nuts and bolts are all snug.
2) Check if the quantity and quality of oil is correct.
3) If the intake filters are dirty, they should be replaced or cleaned.
6
INSTALLATION & OPERATION
Table 1 – Minimum Gauge for Cord
6
10
12
16
Volts
Total length of cord in feet
120V
25ft
18
18
16
14
Plug directly into a
50ft
100ft
AWG
16
16
16
14
16
14
14
Not Recommended
150ft
14
12
12
The

Advertisement

Table of Contents
loading

Table of Contents