Service Modes, Error Codes, and Fault Finding
Upgrade via PC and ComPair interface
It will be possible to upgrade the Stand-by software via a PC
and the ComPair interface. Check paragraph "ComPair" on
how to connect the interface. To upgrade the Stand-by
software, use the following steps:
1. Disconnect the TV from the Mains/AC Power.
2. Short circuit the SPI pins [2] on the SSB. They are located
outside the shielding (see figure "SPI service pads").
3. Keep the SPI pins shorted while connecting the TV to the
Mains/AC Power.
4. Release the short circuit after approx. two seconds.
5. Start up HyperTerminal (can be found in every Windows
application via Programs -> Accessories ->
Communications -> HyperTerminal). Use the following
settings:
–
COM1
–
Bits per second = 38400 (9600)*
–
Data bits = 8
–
Parity = none
–
Stop bits = 1
–
Flow control = None
6. Press "Shift U" on your PC keyboard. You should now see
the following info:
–
PNX2015 Loader V1.0
–
19-09-2003
–
DEVID=0x05
–
Erasing
–
MCSUM=0x0000
–
=
7. If you do not see the above info, restart the above
procedure, and check your HyperTerminal settings and the
connections between PC and TV.
8. Via "Transfer" -> "Send text file ...", you can send the
proper upgrade file to the TV (e.g. *.hex). This file will be
distributed via the Service Organization.
9. After successful programming, you must see the following
info (this can take several minutes!):
–
DCSUM=0xECB3
–
:Ok
–
MCSUM=0xECB3
–
Programming
–
PCSUM=0xECB3
–
Finished
10. If you do not see this info, restart the complete procedure.
11. Close HyperTerminal.
12. Disconnect and connect Mains/AC Power again.
(*) When having problems with upgrading, use the values
between brackets.
Figure 5-22 SPI service pads
2
F_15400_104.eps
110505
BJ3.1E LA
5.
EN 43