Audio Technica ATUC-M58H Instruction Manual page 71

Digital wired conference system, gooseneck microphone with led ring, discussion unit, interpretation unit, control unit, integration unit, link extender, voting unit, ir discussion unit, hybrid control unit, hybrid control unit dante-enabled, ir transmitt
Hide thumbs Also See for ATUC-M58H:
Table of Contents

Advertisement

Web Remote
Unable to control.
34
Number of IRDU exceeds
available IR Bands
35
Dante Communication Error
36
Number of priority units
exceeds maximum. Reduced
37
priority channels.
Unable to set. Number of
priority channels exceeds
38
maximum.
Recording Failed
39
Device ID XXX , Battery 1 Low
40
Device ID XXX , Battery 1
41
Depleted
Device ID XXX , Battery 2 Low
42
Device ID XXX , Battery 2
43
Depleted
Device ID XXX, IRDU Not
Responding
44
45
-
46
-
47
-
48
-
49
-
CU display
(LED indicators)
Unable to Ctrl
Pst Recall Err
Dante Comm Err
-
-
-
-
-
-
-
-
Boot Error XXX
Chg to FreeTalk Mode
Forcible FW Update
Connect USB Device
with FW Update File
Warning 60D
State/remedies
(1) Since recording, recording pause, or file reading process is under way, the
operation cannot be performed.
(2) Due to other reasons, the operation cannot be performed. (Operations
except changing settings cannot be performed.)
• Stop recording and then perform the operation again.
The preset file cannot be read. The number in [Number of Open Mics]
exceeds the number of [IRDU Band] that are enabled.
• Set [Limit NOM to Enabled IR Bands] in [Infrared Settings] to [Off ].
A communication error occurred with the Dante board.
• Turn off the power and restart the system. Confirm that the same error does
not occur when the system is restarted.
The number of DUs which are set as priority DUs exceeded the limit due to
CU Link. Decrease the number of priority DUs. (Deactivate the priority
setting for some DUs.)
• Check the priority DUs and change the setting as necessary.
The maximum number of DUs that can be designated as priority DU is 1 unit
less than the specified value for [Number of Open Mics] ( NOM ). No more
DUs can be designated as a priority DU.
• Change the setting value for the NOM or DU priority setting.
A recording function error occurs such as a recording error not due to
recording operations via Web Remote.
• Check that no error occurs during recording on the CU. If an error occurs,
solve the problem according to the error.
There is low remaining power in battery 1 in the IRDU with device ID XXX.
• Replace battery 1.
There is no remaining power in battery 1 in the IRDU with device ID XXX.
• Replace battery 1.
There is low remaining power in battery 2 in the IRDU with device ID XXX.
• Replace battery 2.
There is no remaining power in battery 2 in the IRDU with device ID XXX.
• Replace battery 2.
There is no response from IRDU with device ID XXX.
• Refer to the installation manual to confirm that the installation environment
for the IRDU and IRA is correct, and then redo the previous operation.
An error occurred while booting the CU. (XXX indicate an error code.)
• Restart the CU and check whether the same error occurs. If the same error
occurs again, the CU requires repair.
Since a communication error occurred with the control device, the conference
mode will be switched to Free Talk Mode where you do not need the control
device.
• Check that there is no network connection problem.
Forced update executes for the CU.
• Follow the message displayed and do not turn off during the update.
Forced update executes (for the CU or the DU).
• Insert a USB control device (mass storage device) where the firmware is
stored to the CU.
Even though DU topology was not changed, the number of connected units
changed.
• Failure may have occurred in a DU in the system. If this occurs frequently,
promptly contact your local Audio-Technica dealer.