The keypad will sound an entry warning beep during this
time to let you and other users know that the area needs
to be disarmed.
If the area is not disarmed before the entry time expires
then an alarm will occur.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [2] + [8] + [1].
A list of available areas will display on the keypad.
A1 Reception Area
A2 Sales Dept
A3 Administration Dept
Press

2. Use the [] and [] keys to select the area that you
want to program the entry time for, then press
[OK] to select. Alternatively, you can enter the area
number that you want to program, then press [OK].
The keypad will display the following:
Entry Time 1 A1
020 Seconds
Press 0-9 OK to SAVE
3. Use the numeric keys to enter the required time in
seconds and then press [OK]. Entry time 1 can be set
from 0 to 255 seconds.
Areas > Timers >

Entry Time 2

This menu allows the master user to modify the entry timer
number 2 for the selected area. Each area in the system
can have a different entry time if required. Your installer
will have set up one or more entry zones per area on your
system and the zones may have been programmed to
follow either entry time 1 or entry time 2.
The entry time is the amount of time you have to turn your
alarm system off once the entry zone have been triggered
or opened.
The keypad will sound an entry warning beep during this
time to let you and other users know that the area needs
to be disarmed.
If the area is not disarmed before the entry time expires
then an alarm will occur.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [2] + [8] + [2].
A list of available areas will display on the keypad.
A1 Reception Area
A2 Sales Dept
A3 Administration Dept
Press

2. Use the [] and [] keys to select the area that you
Bosch Security Systems 10/22 BLCC615U
OK or MENU
MENU 2-8-2
OK or MENU
want to program the entry time for, then press
[OK] to select. Alternatively, you can enter the area
number that you want to program, then press [OK].
The keypad will display the following:
Entry Time 2 A1
040 Seconds
Press 0-9 OK to SAVE
3. Use the numeric keys to enter the required time in
seconds and then press [OK]. Entry time 2 can be set
from 0 to 255 seconds.
Areas > Timers >

Part Entry Time

This menu sets the time period which a keypad will sound
its warning tone after a zone is triggered in Part On or Part
2 On modes. The user must disarm the area before the Part
Entry Time expires, otherwise an alarm condition will be
triggered.
At factory default, when an area has been turned Part On
or Part 2 On and exit time has finished, violating a non 24hr
burglary zone will start the part entry time. The keypad
will sound the hi/lo tone for a period of 60 seconds before
the control panel sound an alarm or until the user turns the
area off.
The part entry time will start when any of the following
zone types area faulted and set to be monitored for Part
On or Part 2 On.
™ Burglary Delay 1
™ Burglary Delay 2
™ Burglary Instant
™ Burglary Inst No Exit
™ Burglary Handover
Only the installer or a master user can set the part entry
time for each area (001 to 255 seconds). Programming 001
seconds allows all non 24 hour burglary zones (including
delay zones) to act as if they were all instant zones when
the area is turned Part On or Part 2 On. Programming 000
seconds allows all non 24 hour burglary zones to operate
as they would if the area has been turned All On.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [2] + [8] + [3].
A list of available areas will display on the keypad.
A1 Reception Area
A2 Sales Dept
A3 Administration Dept
Press

2. Use the [] and [] keys to select the area that you
want to program the entry time for, then press
[OK] to select. Alternatively, you can enter the area
number that you want to program, then press [OK].
Solution 6000-IP
User Guide
MENU 2-8-3