LEAK-CHECK PREPARATION

m WARNING: The gas connections of your Summit
have been factory-tested. We do, however, recommend that
you leak-check all gas connections before operating your
Summit
gas grill.
®
Remove Control Panel
Tools needed: Screwdriver, pliers, and towels .
A) Remove burner control knobs (1) .
B) Open both doors . With a screwdriver, remove screws from the underside of control
panel (2) .
C) Lift and remove battery housing located inside grill cabinet (3) .
D) Using needle-nose pliers, disconnect wire terminals from the top of battery housing
(4) . Do not pull on the wires; remove them by pulling on the wire terminals.
E) Place towels on the tops of both door assemblies . This will protect control panel
and door assemblies from getting scratched on next step.
F) Tilt bottom of control panel forward . Lift slightly (5) and then rotate it face down to
rest on tops of door assemblies . (Be careful not to break or disconnect wires for the
control panel LEDs .)
G) Carefully pull battery wires out from the inside of the grill cabinet (6) .
H) Fully open right door . Place control panel on floor, leaning against towel covering
right door assembly (7) .