Leak Check Preparation - Weber SUMMIT S-620 Owner's Manual

Hide thumbs Also See for SUMMIT S-620:
Table of Contents

Advertisement

Available languages

Available languages

LEAK CHECK PREPARATION

Check That All Burner Valves Are Off
Valves are shipped in the OFF position, but you should check to be sure that they are
turned off . Check by pushing in and turning clockwise . If they do not turn, they are off . If
they do turn continue turning them clockwise until they stop, then they are off .
m WARNING: The gas connections of your Summit
have been factory tested. We do however recommend that
you leak check all gas connections before operating your
Summit
Gas Grill.
®
Remove Control Panel
Tools needed: Screwdriver, pliers, and towels .
A) Remove burner control knobs (1) .
B) Open both doors . With a screwdriver, remove screws from the underside of control
panel (2) .
C) Lift and remove battery housing located inside grill cabinet (3) .
D) Using needle-nose pliers, disconnect wire terminals from the top of battery housing
(4) . Do not pull on the wires; remove them by pulling on the wire terminals.
E) Place towels on the tops of both door assemblies .
This will protect control panel and door assemblies from getting scratched on
next step.
F) Tilt bottom of control panel forward . Lift slightly (5) and then rotate it face down to
rest on tops of door assemblies . (Be careful not to break or disconnect wires for the
control panel LEDs .)
G) Carefully pull battery wires out from the inside of the grill cabinet (6) .
H) Fully open right door . Place control panel on floor, leaning against towel covering
right door assembly (7) .
10
GAS INSTRUCTIONS
Gas Grill
®
1
4
2
3
The grills illustrated in this
Owner's Guide may vary slightly
from the model purchased .

Advertisement

Table of Contents
loading

This manual is also suitable for:

Summit e-620

Table of Contents