Canon imageCLASS X LBP1238 II Service Manual page 182

Hide thumbs Also See for imageCLASS X LBP1238 II:
Table of Contents

Advertisement

■ CLEAR
COPIER (Service mode for printer) > FUNCTION (Operation / inspection mode) > CLEAR
SRVC-DAT
Detail
Adj/Set/Operate Method
COUNTER
Detail
Adj/Set/Operate Method
HIST
Detail
Use Case
Adj/Set/Operate Method
ALL
Detail
Use Case
Adj/Set/Operate Method
Default Value
Related Service Mode
ERDS-DAT
Detail
Use Case
Adj/Set/Operate Method
Caution
Related Service Mode
Supplement/Memo
PLPW-CLR
Detail
Use Case
Adj/Set/Operate Method
Clearing of service mode setting values
To clear the service mode setting values.
The user mode setting values are not cleared.
The factory adjustment values of the Reader/DADF are not initialized.
1) Select the item, and then press Yes key.
2) Turn OFF/ON the main power switch.
Clearing of service counter
To clear the counter by maintenance/part.
The numerator printed on a system dump list becomes 0.
1) Select the item, and then press Yes key.
2) Turn OFF/ON the main power switch.
Clearing of logs
To clear the communication management/print/jam/alarm/error log.
When clearing logs
1) Select the item, and then press Yes key.
2) Turn OFF/ON the main power switch.
Clearing of setting information
To clear/initialize the following setting information according to the location set in LOCALE and
SIZE-LC.
- User mode setting values
- Service mode setting values (excluding the service counter)
- ID and password of the system administrator
- Communication management/print/jam/alarm/error log
- E719 error (counter meter-installed models only)
The following items are not cleared/initialized.
- Service counter
- Factory adjustment values of the Reader/DADF
At installation
1) Select the item, and then press Yes key.
2) Turn OFF/ON the main power switch.
0
COPIER > OPTION > BODY > LOCALE, SIZE-LC
COPIER > FUNCTION > CLEAR > E719-CLR
Initialize of Embedded-RDS setting value
To initialize the Embedded-RDS setting values.
ON/OFF of Embedded-RDS, Remote Monitoring Server port number and communication error log
set in ERDS, RGW-PORT, and COM-LOG are cleared.
When upgrading the Bootable in the Embedded-RDS environment
Select the item, and then press Yes key.
Use of the SRAM in Embedded-RDS differs depending on the Bootable version. Therefore, unless
initialization is executed at the time of version upgrade, data inconsistency occurs.
COPIER > FUNCTION > INSTALL > ERDS, RGW-PORT, COM-LOG
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to Remote Monitoring Server via SOAP protocol
Clear security policy setting password
To clear the password of the security administrator set in the security policy settings.
When clearing the password of the security administrator
Select the item, and then press Yes key.
172