Download Print this page

Sanyo VCC-XZ600P Instruction Manual page 2

Hide thumbs Also See for VCC-XZ600P:

Advertisement

Shape
Color
One-touch
RED
1
connector
WHITE
BROWN
GRAY
ORANGE/BLACK RS485 (B)
Individual
SKYBLUE
2
cables
PINK
GRAY/BLACK
BLACK
BLUE
YELLOW
ORANGE
BNC
COAXIAL CABLE VIDEO OUT
3
connector
For the cable type, see the "cable label" attached to the cable bundle.
Follow the steps below to connect each cable firmly to the one-touch connector.
Signal Name
Use
24 VAC/12
Used to connect the power supply.
VDC (+)
24 VAC/12
VDC (–)
COMMON
Earth terminal
RS485 (A)
Used to connect the system controller or other external system component.
For connection, use cables with 22AWG wire or thicker.
UTP (+)
Use these twisted pair cables to output the video signal to an external device.
UTP (–)
ALARM IN 1
Used to connect alarm switch, infrared sensor, or other external devices.
To automatically switch between the color and black/white modes, select
[DAY/NIGHT], choose the "COLOR" mode, and then set the "EXT ALARM" to
ALARM IN 2
an appropriate input level.
ALARM OUT Used to connect a buzzer, lamp, video recorder, or other peripheral device.
To control the alarm output externally from a remote location, on the ALARM
OUT screen, select [OUTPUT] and choose "REMOTE.".
FOCUS
Used to adjust the camera focus by external voltage control.
DC ± (6 to 12 V), +: FAR/-: NEAR
ZOOM
Used to adjust the camera zoom by external voltage control.
DC ± (6 to 12 V), +: WIDE/-: TELE
Used to connect to the VIDEO IN connector of your monitor.
2 / 100

Advertisement

loading