Product Specific & Important Safety Information; Appliance Certification; Btu Specifications And Weight; Gas Pressures - Hearth and Home Technologies outdoor lifestyles LUM-OD-NM Installation & Owner's Manual

Table of Contents

Advertisement

1 1
Product Specific and Important Safety Information
A. Appliance Certification
LUM-OD-NM, LUM-OD-PM
MODEL:
LABORATORY: Underwriters Laboratory (UL)
TYPE: Outdoor Decorative Gas Appliance
STANDARD: ANSI Z21.97-2017, CSA 2.41-2017
This product is listed to ANSI standards for "Unvented
Room Heaters" and applicable sections of "Gas Burning
Heating Appliances for Manufactured Homes" and "Gas
Fired Appliances for Use at High Altitude."
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heater or as a decorative appliance. It should not
be factored as primary heat in residential heating calcula-
tions.
B. BTU Specifications and Weight
Models
LUM-OD-NM
(0-2000 FT)
LUM-OD-PM
(0-2000 FT)
4
Maximum
Minimum
Input
Input
Orifice
BTU/h
BTU/h
.136 in
38,000
19,000
(3.45mm)
#29
.0.78 in
38,000
31,000
(1.98mm)
#47
Outdoor Lifestyles • Lumonessen Owner's /Installation Manual • 4629-900 Rev. A • 02/23
NOTE: For LP models an external regulator is required
to reduce supply pressure to a maximum of 13" w.c.
C. Gas Pressures
Inlet Minimum
Inlet Maximum
Gas Valve Manifold
Pressure Setting
NATURAL GAS: An external regulator is required to reduce
supply pressure to a maximum of 10
systems operating at higher pressure.
PROPANE/LPG: An external regulator is required to reduce
supply pressure to a maximum of 13" w.c.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation: Reduce input
rate 4% for each 1000 feet above sea level.
Check with your local gas utility to determine proper
Weight
Pounds
orifice size.
7
E. Non-Combustible Materials Specification
Material which will not ignite and burn. Such materials are
7
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750 ºC shall be considered
non-combustible materials.
NATURAL
PROPANE (LP)
5.0" w.c.
11.0" w.c.
10.5" w.c.
13.0" w.c.
3.5" w.c.
10" w.c.
" w.c. on natural gas
1