Download Print this page
Aiphone C-123LW Supplemental Instructions
Aiphone C-123LW Supplemental Instructions

Aiphone C-123LW Supplemental Instructions

Dual master chimecom system

Advertisement

Quick Links

C-123LW Supplemental Instructions
- REFER TO INSTALLATION MANUAL INSIDE C-123L/A BOX FOR STANDARD
The C-123LW Dual Master ChimeCom set provides chime, communication, and door release for one door and two
inside locations. This supplemental instruction manual addresses many of the additional functions and modifi cations
for the Chime Com system, including installation and troubleshooting information.
MASTER STATION:
C-ML/A:
Master station with door release button (Normally Open)
COMPATIBLE DOOR STATIONS: (Weather resistant, made for outdoor use)
C-D
Surface mount, included in C-123L/A and C-123LW kit
LE-D
Surface mount, plastic door station (replacement for C-D)
LE-DA
Flush mount in 2-gang box, stainless steel cover
LE-SS-1G
Vandal resistant, 1-gang fl ush mount, stainless steel
LE-SS
Vandal resistant, 2-gang fl ush mount, stainless steel
LE-SSR
Vandal resistant, 2-gang fl ush mount, stainless steel, red mushroom button
LS-NVP/C
Vandal resistant, 3-gang fl ush mount, white powder-coat fi nish
OPTIONAL COMPONENTS & ACCESSORIES:
RY-AC/A
External signaling relay (Requires 12VDC power supply)
DAK-2S
Dual master adaptor kit (2component modules)
(1 kit per 2 master stations. Use 2 DAK-2S for up to 4 total master stations)
SBX-1G
Surface mount box for LE-SS-1G
SBX-2G
Surface mount box for LE-SS, LE-SSR, LE-DA
SBX-NVP
Surface mount box for LS-NVP/C
EL-12S
Door strike (for interior wood frame doors only)
PT-1210N
AC 12V Transformer (used for door strike)
SKK-620B
6V DC power supply (1 per C-ML/A master)
822202
2 conductor, 22AWG, Shielded wire for up to 245', (500' and 1000' boxes)
821802
2 conductor, 18AWG, Shielded wire for up to 590', (1000' box)
Install two separate runs of this cable, one for the intercom and one for
the door release.
DOOR RELEASE WIRES MUST BE IN A SEPARATELY JACKETED CABLE FROM THE INTERCOM WIRING.
C-D
Power source and Door Strike not included.
IMPORTANT: Connect wires
Separate 2 conductor for door release
EL-12S, not included with the C-123L/A or C-123LW set.
Dual Master ChimeCom System
INSTALLATION INFORMATION -
C-123LW Set contains:
2 C-ML/A, 1 C-D, 1 DAK-2S
2 cond. shielded for intercom
before applying power.
90102
0610
C-ML/A
Power
Source
for Strike
C-123L/A Set
LE-SS-1G
LE-DA
LS-NVP/C
LE-SS
DAK-2S
(2 component modules per kit)
SKK-620B
(or 4 "C" batteries installed in
the master). Do not use both
power sources. Ground wire
must be tied to earth ground
when using the SKK-620B.
C-123LW Supplement
Pg. 1

Advertisement

loading

Summary of Contents for Aiphone C-123LW

  • Page 1 - REFER TO INSTALLATION MANUAL INSIDE C-123L/A BOX FOR STANDARD The C-123LW Dual Master ChimeCom set provides chime, communication, and door release for one door and two inside locations. This supplemental instruction manual addresses many of the additional functions and modifi cations for the Chime Com system, including installation and troubleshooting information.
  • Page 2 10. The door release button on the master station is a “Normally Open” contact closure for an electric strike. See page 3 for modifi cation to “Normally Closed” if a magnetic lock is used. 4 C-ML/A Master Stations with 1 Door Component Module SKK-620B C-123LW Supplement Pg. 2 C-ML/A Component Module* C-ML/A...
  • Page 3 White RY-AC Black Power source for bell To 1 of C-ML/A C-ML/A Rear View with PC board removed. Door release switch C-123LW Supplement BELL Pg. 3...
  • Page 4: Troubleshooting Guide

    Master stays on; does not time out. Voice volume is too loud or too soft. Chime tone volume is too loud. RY-AC external signaling relay not working. Aiphone Communcation Systems 1700 130th AVE N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071...