Download Print this page
Aiphone DUAL MASTER CHIMECOM SYSTEM C-123LW Supplemental Instructions

Aiphone DUAL MASTER CHIMECOM SYSTEM C-123LW Supplemental Instructions

Dual master chimecom system

Advertisement

Quick Links

- REFER TO INSTALLATION MANUAL INSIDE C-123L/A BOX FOR STANDARD
The C-123LW Dual Master ChimeCom set provides chime, communication, and door release for one door and two
inside locations. This supplemental instruction manual addresses many of the additional functions and modifications
for the Chime Com system, including installation and troubleshooting information.
MASTER STATION:
C-ML/A
Master station with door release button (Normally Open)
COMPATIBLE DOOR STATIONS: (Weather resistant, made for outdoor use)
C-D
Surface mount, included in C-123/A and C-123LW kit
LE-D
Surface mount, plastic door station (replacement for C-D)
LE-DA
Flush mount in 2-gang box, stainless steel cover
LE-SS-1G
Vandal & weather resistant, 1-gang flush mt, stainless steel
LE-SS
Vandal & weather resistant, 2-gang flush mt, stainless steel
LS-NVP/B
Vandal & weather resistant, 3-gang flush mt, white powder-coat finish
OPTIONAL COMPONENTS & ACCESSORIES:
RY-AC/A
External signaling relay
(Requires 12VDC, 500mA power supply, locally available)
DAK-2S
Dual master adaptor kit (2 component modules)
(1 kit per 2 master stations. Use 2 DAK-2S for up to 4 total masters stations)
SBX-SS-1G
Surface mount stainless steel box for LE-SS-1G
SBX-2G
Surface mount stainless steel box for LE-SS, LE-DA
SBX-NVP
Surface mount box for LS-NVP/B
EL-9S
Door strike (for interior wood frame doors only)
PT-1210N
AC 12V Transformer (for EL-9S)
822202
2 conductor, 22AWG, Shielded wire for up to 245', (500' and 1000' boxes)
821802
2 conductor, 18AWG, Shielded wire for up to 590', (1000' box)
Install two separate runs of cable, one for the intercom and one for
the door release.
DOOR RELEASE WIRES MUST BE IN A SEPARATELY JACKETED CABLE FROM THE INTERCOM WIRING.
Power source and Door strike not included.
C-D
Separate 2 conductor for door strike
EL-9S, not included with the C-123L/A or C-123LW set.
Dual Master ChimeCom System
INSTALLATION INFORMATION -
C-123LW Set contains:
2 C-ML/A, 1 C-D, 1 DAK-2S
2 cond. shielded for intercom
90102
0906
(2 component modules per kit)
C-ML/A
(or 4 "C" batteries installed in
the master). Do not use both
C-123L/A Set
LE-DA
LE-SS-1G
LE-SS
LS-NVP/B
DAK-2S
SKK-620
power sources.
Pg. 1

Advertisement

loading

Summary of Contents for Aiphone DUAL MASTER CHIMECOM SYSTEM C-123LW

  • Page 1 Dual Master ChimeCom System - REFER TO INSTALLATION MANUAL INSIDE C-123L/A BOX FOR STANDARD The C-123LW Dual Master ChimeCom set provides chime, communication, and door release for one door and two inside locations. This supplemental instruction manual addresses many of the additional functions and modifications for the Chime Com system, including installation and troubleshooting information.
  • Page 2 WIRING DIAGRAM: Dual Master Chime Com System with DAK-2S Dual Master Adaptor Please read and understand all instructions before installation. Door EL-9S IMPORTANT!!! Each master REQUIRES an SKK-620 power supply, or 4 "C"batteries. OPERATION NOTES: 1. Only one master can be used at a time. 2.
  • Page 3 C-ML/A 12V DC power supply Component Module* If a DAK-2S is not available, install components as shown below. Capacitor: 25V, 15-33mfd Non-polarized (Aiphone NP-25V) Diode: 1N 4148 To 1 of C-D and WHITE wire of RY-AC Output of RY-AC (Yellow...
  • Page 4: Troubleshooting Guide

    7 Master stays on; does not time out. 8 Voice volume is too loud or too soft. 9 Chime tone volume is too loud. 10 RY-AC external signaling relay not working. Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510...