en Installation instructions
¡ After installation of the shield the clearance around
the top and sides of shield will allow adequate vent-
ilation. Ensure the side and top clearances are not
obstructed.
2.5 Positioning the appliance
Note: Do not remove the adhesive seal fitted on the
lower edge of the cooktop. The adhesive seal prevents
the penetration of liquids.
Do not use silicone to bond the appliance to the work-
top.
Position the cooktop with the upper side facing
1.
down on a flat, stable surface.
Loosen the screws on the brackets so they can turn
2.
freely. You do not need to fully undo the screws on
the brackets.
Turn the cooktop around and insert it into the re-
3.
cess. Insert the cooktop in the front of the recess.
Turn the brackets and tighten them fully.
4.
The position of the brackets depends on the work-
top thickness.
8
2.6 Electrical connection
Follow the instructions for electrical connection.
¡ An electrical 10 amp socket needs to be within 1 m
of the hotplate to allow electrical connection. The
socket must remain accessible after installation of
the appliance.
¡ This appliance is connected to the mains (240 VAC)
by means of the connecting lead. The connecting
lead must be fixed to the kitchen unit to prevent it
from coming into contact with hot parts of the cook-
top or an oven installed underneath and remain ac-
cessible after installation of the cooktop.
¡ This appliance must be earthed. When connecting
the cooktop ensure that the earth wire is connected
first and that all wires are connected to the correct
terminals.
Wiring diagram
Observe the wiring diagram.
a
Switch
b
Blue wire
c
Brown wire
d
Terminal
e
Ignition module
2.7 Gas connection
Only an officially authorised technician should connect
the appliance.
Before connecting the gas
Observe any special conditions imposed by local sup-
pliers (utilities).
¡ During the planning stage, consider the position of