Hour Meter; Connection Plugs; Cosense - Generac Power Systems GP Series Owner's Manual

Hide thumbs Also See for GP Series:
Table of Contents

Advertisement

Available languages

Available languages

Hour Meter

See
2-4. The Hour Meter tracks hours
Figure
of operation for scheduled maintenance.
• The CHG OIL display will illuminate every
100 hours. The message will flash one hour
before and one hour after each 100 hour
interval, providing a two hour window to
perform service.
• The SVC display will illuminate every 100
hours. The message will flash one hour
before and one hour after each 200 hour
interval providing a two hour window to per-
form service.
When the hour meter is in flash alert mode,
the maintenance message will alternate with
elapsed time in hours and tenths. The hours
will flash four times, then alternate with the
maintenance message four times until the
meter automatically resets.
• 100 hours - CHG OIL — Oil Change Inter-
val (Every 100 hrs)
• 200 hours - SVC — Service Air Filter
(Every 200 hrs)
NOTE: The hour glass icon will flash when the
engine is running. This signifies the meter is
recording hours of operation.
0000.0
Figure 2-4. Hour Meter

Connection Plugs

120 VAC, 20 Amp, GFCI Duplex
Receptacle
See
Figure
2-5. The 120 Volt outlet is overload
protected by a 20 Amp push-to-reset circuit
breaker. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater). It also pro-
vides protection with a Ground Fault Circuit
Interrupter with a press to TEST and RESET
button.
Owner's Manual for Portable Generator
Figure 2-5. 120 VAC, 20 Amp, GFCI Duplex
120/240 VAC, 30 Amp Receptacle
See
Figure
with this receptacle (rotate to lock/unlock).
Connect a suitable 4-wire grounded cord set
to plug and desired load. The cord set should
be rated 250 Volts AC at 30 Amps (or
greater).
Use this receptacle to operate 120 Volt AC, 60
Hz, single phase loads requiring up to 3600
watts (3.6 kW) of power at 30 Amps or 240
Volt AC, 60 Hz, single phase loads requiring
up to 7200 watts (7.2 kW) of power at 30
Amps. The outlet is protected by one 30 Amp
2-pole circuit breaker.
000205
Figure 2-6. 120/240 VAC, 30 Amp Receptacle

COsense

Carbon Monoxide (CO) Detection
and Shut-off System (if equipped)
The COsense module monitors for the accu-
mulation of poisonous CO gas found in engine
exhaust when the generator is running. If
COsense detects increasing levels of CO gas,
it automatically shuts off the engine. COsense
only monitors when the engine is running.
Generators are intended to be used outdoors,
far from occupied buildings and the exhaust
pointed away from personnel and buildings.
However, if mis-used and operated in a loca-
tion that results in the accumulation of CO, like
indoors or in a partially enclosed area,
Receptacle NEMA 5-20R
2-6. Use a NEMA L14-30 plug
NEMA L14-30R
®
000203
000204
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp7500e df-co

Table of Contents