Hour Meter; Connection Plugs - Generac Power Systems GP3300 Series Owner's Manual

Hide thumbs Also See for GP3300 Series:
Table of Contents

Advertisement

Available languages

Available languages

Hour Meter

See
2-3. The Hour Meter tracks hours
Figure
of operation for scheduled maintenance.
• The CHG OIL display will illuminate every
100 hours. The message will flash one hour
before and one hour after each 100 hour
interval, providing a two hour window to
perform service.
• The SVC display will illuminate every 100
hours. The message will flash one hour
before and one hour after each 200 hour
interval providing a two hour window to per-
form service.
When the hour meter is in flash alert mode,
the maintenance message will alternate with
elapsed time in hours and tenths. The hours
will flash four times, then alternate with the
maintenance message four times until the
meter automatically resets.
• 100 hours - CHG OIL — Oil Change Inter-
val (Every 100 hrs)
• 200 hours - SVC — Service Air Filter
(Every 200 hrs)
NOTE: The hour glass icon will flash when the
engine is running. This signifies the meter is
recording hours of operation.
0000.0
Figure 2-3. Hour Meter

Connection Plugs

120 VAC, 20 Amp, GFCI Duplex
Receptacle
See
Figure
2-4. The 120 Volt outlet is overload
protected by a 14 Amp, 2-pole push-to-reset
circuit breaker. Each receptacle will power 120
Volt AC, single phase, 60 Hz electrical loads
requiring up to 1680 watts (1.68 kW) or 14
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater). It also pro-
vides protection with a Ground Fault Circuit
Interrupter with a press to TEST and RESET
button.
Owner's Manual for Portable Generator
Figure 2-4. 120 VAC, 20 Amp, GFCI Duplex
120/240 VAC, 20 Amp Twistlock
Receptacle
See
Figure
protected against overload by a 14 Amp, 2-
pole circuit breaker. Connect a suitable 4-wire
grounded cord set to the plug and to the
desired load. The cord set should be rated for
250 volts at 20 amps (or greater) if the 120/
240 receptacle is used along with 120 volt
receptacle. The total load drawn must not
exceed the data label ratings.
000205
Figure 2-5. 120/240 VAC, 20 Amp Receptacle
Receptacle NEMA 5-20R
2-5. This is a 120/240 Volt outlet
000203
000625
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

006431r1

Table of Contents