Lincoln Electric INVERTEC 400TP Operator's Manual page 5

Table of Contents

Advertisement

Typical gas usage for MIG/MAG equipment:
Wire
Material type
diameter
[mm]
Carbon, low
0,9 ÷ 1,1
alloy steel
Aluminium
0,8 ÷ 1,6
Austenic
0,8 ÷ 1,6
stainless steel
Copper alloy
0,9 ÷ 1,6
Magnesium
1,6 ÷ 2,4
TIG Process:
In TIG welding process, gas usage depends on cross-sectional area of the nozzle. For commonly used torches:
Helium: 14-24 l/min
Argon: 7-16 l/min
Notice: Excessive flow rates causes turbulence in the gas stream which may aspirate atmospheric contamination into the
welding pool.
Notice: A cross wind or draft moving can disrupt the shielding gas coverage, in the interest of saving of protective gas use
screen to block air flow.
End of life
At end of life of product, it has to be disposal for recycling in accordance with Directive 2012/19/EU (WEEE), information
about the dismantling of product and Critical Raw Material (CRM) present in the product, can be found at
https://www.lincolnelectric.com/en-gb/support/Pages/operator-manuals-eu.aspx
English
DC electrode positive
Current
Voltage
[A]
[V]
95 ÷ 200
18 ÷ 22
90 ÷ 240
18 ÷ 26
85 ÷ 300
21 ÷ 28
175 ÷ 385
23 ÷ 26
70 ÷ 335
16 ÷ 26
Wire Feeding
Shielding Gas
[m/min]
3,5 – 6,5
Ar 75%, CO
5,5 – 9,5
Ar 98%, O
3 - 7
He 90%, Ar 7,5% CO
6 - 11
4 - 15
3
Gas flow
[l/min]
25%
12
2
Argon
14 ÷ 19
2% /
2
14 ÷ 16
2,5%
2
Argon
12 ÷ 16
Argon
24 ÷ 28
English

Advertisement

Table of Contents
loading

Table of Contents