Universal programmable controller
Hide thumbs Also See for TCI2:

Advertisement

Quick Links

V
ECTOR
Wi
Fi
Universal Programmable Controller TCI2
The TCI2 is a programmable universal controller with communication capabilities. Each control loop may use 2 PI sequences
and 2 binary stages. The TCI2 comes with a built-in RS485 communication interface that allows peer-to-peer communication
with an operation terminal such as OPA2-(2TH)-VC. The TCI2 uses the universal X2 operating system. Serial communication
options are realized with Modbus RTU/ASCII and BACnet MS/TP. There is also a Wi-Fi and Ethernet communication option
available which supports Modbus TCP and BACnet IP. An embedded webserver provides a web interface to access the
controller in order to change the connection settings and to operate the controller.
Complete parameter sets may be copied by use of an accessory called AEC-PM2 or exchanged with a PC using an RS485-USB
converter, Wi-Fi or Ethernet communication and the EasySet program.
Functions
Two universally configurable control loops:
Functions for dehumidifying, set point shift and cascade control
o
Multiple auxiliary functions: heat-cool auto changeover, automatic enable, set point compensation
o
Free heating and cooling with economizer function based on enthalpy or temperature
o
Differential, averaging, min and max functions, enthalpy and dew point calculations
o
Transmitter function for inputs and set points
o
4 selectable universal inputs (VDC, mA, NTC, Pt1000) and 2 analog outputs (VDC, mA)
2 relays with each a normally open contact (SPST NO)
8 freely assigned alarm conditions, selectable state of outputs on alarm condition
Power Cap protected real-time clock with 48hr power backup
7-day programmable schedules, with options including change of set points and direct position of manual outputs
Password protected programmable user and control parameters
Peer to peer communication to optional X2 operation terminal OPxx-VC
Communication over Modbus, BACnet, Ethernet or Wi-Fi (optional interface required)
Webserver that supports TCI2 operation trough mobile devices or EasySet IP access (Ethernet or Wi-Fi interface
required)
Doc: 70-07-0703B, 20220426
Subjects to alteration
© Vector Controls LLC, USA
www.vectorcontrols.com
TCI2
P
D
S
RODUCT
ATA
HEET
Page 1-10

Advertisement

loading

Summary of Contents for Vector TCI2

  • Page 1 HEET Universal Programmable Controller TCI2 The TCI2 is a programmable universal controller with communication capabilities. Each control loop may use 2 PI sequences and 2 binary stages. The TCI2 comes with a built-in RS485 communication interface that allows peer-to-peer communication with an operation terminal such as OPA2-(2TH)-VC.
  • Page 2 40-500146 Antenna cable kit for external mounting of the Wi-Fi antenna (cable length 1 m) Mounting AMM-2 40-510023 Mounting kit for panel mounting of the TCI2 Memory AEC-PM2 40-500103 Plug-In memory module for saving and fast copying of parameter sets...
  • Page 3: Technical Specifications

    Dimensions (H x W x D) 57 x 93 x 115 mm (2.4 x 3.7 x 4.5) inch Weight (including package) TCI2 (24V) without display / with display 245g (8.6oz) / 290g (10.2oz) TCI2 (230V without display / with display 275g (9.7oz) / 320g (11.3oz)
  • Page 4 WiFi-Antenna only on -WEM, -WEB 57 (2.2) 93 (3.7) 45 (1.8) Reset button TCP/IP only on –WEM, -WEB, -ETM, -ETB Status-LED Ethernet plug only on -ETM , -ETB Doc: 70-07-0703B, 20220426 © Vector Controls LLC, USA Page 4-10 Subjects to alteration www.vectorcontrols.com...
  • Page 5: Mounting And Installation

    See the TCI2 installation sheet, document no. 70-00-0688 or 70-00-0893 (www.vectorcontrols.com). Selection of sensors and actuators Temperature sensors  Use Vector Controls NTC sensors to achieve maximum accuracy: SDB-Tn10-20 (duct), SRA-Tn10 (room), SDB-Tn10-20 + AMI-S10 as immersion sensor. Actuators ...
  • Page 6 Rest button TCP/IP (-WEM, -WEB, -ETM, -ETB only) The TCP/IP configuration setting of the TCI2 can be reset by pressing the reset button with a 1 mm pin through the small hole located next to the Status-LED. The function of the TCP/IP reset is explained in the X2 Wi-Fi / Ethernet Configuration Manual.
  • Page 7: Operation And Configuration

    70-07-0174 Product data sheet (this document) TCI2 Install Sheet 70-00-0688 Mounting and installation manual -OP, -MOD, -BAC TCI2 Install Sheet TCP/IP 70-00-0893 Mounting and installation manual -WEM, -WEB, -ETM, -ETB X2 Operations Manual button display 70-07-0950 Operations instructions of X2 system with button display...
  • Page 8: Bacnet Protocol Implementation Conformance Statement (Pics)

    Product Name: TCI2 Controls series TCI2 product description: The TCI2 communicating BACnet controllers are designed as universal controls equipment suitable for a large number of applications. They may be used in zoning and other applications which are monitored by a BACnet MS/TP network.
  • Page 9 Real time clock module with 48-hour power back up (keeps clock running during power failure) Pr01 to Pr12 Time schedule programs for 7 days or annual switching events Doc: 70-07-0703B, 20220426 © Vector Controls LLC, USA Page 9-10 Subjects to alteration www.vectorcontrols.com...