Alignment
Noise Blanker Circuit Adjustment
Set the following controls as indicated:
[ANT 1/2] button: ANT 1
[IPO] button: AMP1
[ATT] button: OFF
[AGC] button: "Sub band (VFO-B)"AUTO
[NB] button: "Sub band (VFO-B)" ON
(for short-duration pulse noise)
[NB] knob: Fully clockwise
[RF GAIN] knob: Fully clockwise
[SUB RX] button: ON
Set the Sub Band (VFO-B) frequency to 14.200
MHz in the CW mode.
Connect the DC voltmeter to TP4505 on the RX-2
Unit.
Connect the RF Signal Generator to the "ANT 1"
jack, then set the output level to 30 dBµ at the
14.200 MHz.
Adjust T4508 and T4512 on the RX-2 Unit for
minimum deflection on the DC voltmeter.
Turn the Sub band´s (VFO-B) NB to "OFF" by
pressing the [B] button followed by the [NB] but-
ton.
IF Gain Adjustment
Set the following controls as indicated:
[ANT 1/2] button: ANT 1
[IPO] button: AMP1
[ATT] button: OFF
[AGC] button: "Sub band (VFO-B)"AUTO
[PITCH] knob: 700 Hz
[RF GAIN] knob: Fully clockwise
[SUB RX] button: ON
Connect the AC millivoltmeter and 4 Ohm
dummy load to the EXT SP jack.
Connect the RF Signal Generator to the "ANT 1"
jack, then set the output level to 36 dBµ at the
1.900 MHz.
Set the Sub Band (VFO-B) frequency to 1.900 MHz
in the CW mode.
Press and hold in the [1(1.8)], [2(3.5)], and [3(7)]
keys, while turning the radio on, to enter the
alignment mode.
Adjust the Sub [AF GAIN] knob so that the AC
millivoltmeter reading is "0 dB."
ALIGNMENT-10
Select the appropriate "Alignment Parameter"
using the Main Tuning Dial knob per the chart
below, then set the RF Signal Generator output
to each listed level, and adjust the [SUB(VFO-B)]
knob for the corresponding AC millivoltmeter
reading at each frequency.
A
P
RF S
LIGNMENT
ARAMETER
IGNAL
C01 iGn
1.900 MHz, 9 dBµ
C02 iGn
3.750 MHz, 9 dBµ
C03 iGn
7.150 MHz, 9 dBµ
C04 iGn
10.125 MHz, 9 dBµ
C05 iGn
14.175 MHz, 9 dBµ
C06 iGn
18.117 MHz, 9 dBµ
C07 iGn
21.255 MHz, 9 dBµ
C08 iGn
24.940 MHz, 9 dBµ
C09 iGn
28.850 MHz, 9 dBµ
C10 iGn
52.000 MHz, 9 dBµ
Press and hold in the [MENU] button for 2 sec-
onds to save the new setting and exit from the
alignment mode.
S-meter Adjustment
Set the following controls as indicated:
[ANT 1/2] button: ANT 1
[IPO] button: AMP1
[ATT] button: OFF
[AGC] button: "Sub band (VFO-B)"AUTO
[RF GAIN] knob: Fully clockwise
[SUB RX] button: ON
Connect the RF Signal Generator to the "ANT 1"
jack, then set the frequency to 14.200 MHz.
Set the Sub Band (VFO-B) frequency to 14.200
MHz in the CW mode.
Press and hold in the [1(1.8)], [2(3.5)], and [3(7)]
keys, while turning the radio on, to enter the
alignment mode.
Select the appropriate "Alignment Parameter"
using the Main Tuning Dial knob per the chart
below, then set the RF Signal Generator output
to each listed level, and adjust the [SUB(VFO-B)]
knob until the corresponding Sub S-meter indi-
cator just lights (i.e. Adjust to the lowest value of
each "S" unit range), then press the [ENT] key to
save the new setting at each frequency.
A
P
RF S
LIGNMENT
ARAMETER
C11 S-0
C12 S-1
C13 S-5
C14 S-7
C15 S-9
C16 S10
C17 S20
C18 S30
C19 S40
C20 S50
C21 S60
G
VFO-B F
AC
ENERATOR
REQUENCY
MILLIVOLTMETER
1.900 MHz
–1.5 dB (±0.5 dB)
3.750 MHz
–1.5 dB (±0.5 dB)
7.150 MHz
–1.5 dB (±0.5 dB)
10.125 MHz
–1.5 dB (±0.5 dB)
14.175 MHz
–1.5 dB (±0.5 dB)
18.117 MHz
–1.5 dB (±0.5 dB)
21.255 MHz
–1.5 dB (±0.5 dB)
24.940 MHz
–1.5 dB (±0.5 dB)
28.850 MHz
–1.5 dB (±0.5 dB)
52.000 MHz
–1.5 dB (±0.5 dB)
G
S
S-
IGNAL
ENERATOR
UB
METER
9 dBµ
One dot
12 dBµ
S-1
24 dBµ
S-5
30 dBµ
S-7
36 dBµ
S-9
46 dBµ
S-9+10dB
56 dBµ
S-9+20dB
66 dBµ
S-9+30dB
76 dBµ
S-9+40dB
86 dBµ
S-9+50dB
96 dBµ
S-9+60dB