Engine Stop Procedure
1. Except for special cases, before stopping the engine,
lower the bucket and blade to the ground.
2. Pull pilot control shut-off lever (3) to LOCK position.
3. Turn engine control dial (1) to the slow idle position and
run the engine for 5 minutes to cool the engine.
IMPORTANT: If the engine equipped with a turbocharger
is stopped without first performing the cool down
operation, the lubricant on the turbocharger bearing
surfaces may desiccate due to the intense heat present
inside the turbocharger, possibly causing damage to
the turbocharger.
Do not idle for excessively long periods.
Observe local and federal engine idling regulations.
4. Turn key switch (2) OFF to stop the engine.
If the engine does not stop, even if the key switch is
turned to the OFF position. (Emergency Stop)
In case the engine does not stop even if key switch (2) is
turned OFF due to failure of the machine, move engine stop
switch (4) downward to stop the engine. The engine will
stop. Return engine stop switch (4) to its original position
(upward).
d
CAUTION: Do not use engine stop switch (4) unless
absolutely necessary. When the machine stops due to
machine failure, do not start the machine until repair is
completed
IMPORTANT: The DEF/AdBlue® pump runs for a while
after the engine stops to return DEF/AdBlue® from
piping to the DEF/AdBlue® tank. Do not turn battery
disconnect switch to the OFF position during this time.
Otherwise, the Urea SCR system may be damaged.
OPERATING THE ENGINE
3-13
3
LOCK Position
Slow Idle
2
4
SA-2590
MDCN-01-008
1
M1P1-01-068
MDC1-01-502
MDCN-01-004

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zaxis 225us-6 classZaxis 345us-6 classZaxis 135us-6Zaxis 225uslc-6Zaxis 345uslc-6

Table of Contents