Bradford White ULG2100H805N Installation/Operation Instruction Manual page 26

Gas-fired water heater
Table of Contents

Advertisement

TROUBLESHOOTING CHART – HONEYWELL V1 continued.
LED Status
Five flashes and three
second pause.
Six flashes and three
second pause.
Seven flashes and three
second pause.
Eight flashes and three
second pause.
Control Status
Temperature sensor fault.
Water leak detected by
accessory module (some
models).
Gas valve electronic fault
detected.
False pilot flame present.
26
Probable Cause
1. Damage to the
temperature wire.
2. Temperature sensor
resistance out of range.
3. Replace temperature
sensor.
4. If temperature sensor
replacement does not
correct the problem;
verify control is not wet
or physically damaged.
5. Turn set point knob to
"OFF" position. Turn
set point knob to
"PILOT" position and
light pilot.
6. Replace gas valve if
five flash error persists.
Excessive amount of water
in drain pan/water dam.
1. Verify control is not wet
or physically damaged.
2. Turn set point knob to
"OFF" position. Turn
set point knob to
"PILOT" position and
light pilot.
3. Replace gas valve if
seven flash error
persists.
1. Pilot valve stuck in
open position.
2. Turn set point knob to
"OFF" position. Turn
set point knob to
"PILOT" position and
light pilot.
3. Replace gas valve if
eight flash error
persists.