Connecting Cascade Cables; Figure 15 Cascade Cable Connection - Fujitsu ETERNUS AF Series Configuration Manual

All-flash arrays, hybrid storage systems, disk storage systems, power synchronized unit
Hide thumbs Also See for ETERNUS AF Series:
Table of Contents

Advertisement

4.
Connection and Settings

Connecting Cascade Cables

Connecting Cascade Cables
When two power synchronized units are cascaded, use the cascade cable to connect the power synchronized
units.
Cascade cables must be purchased separately.
A connection figure for the cascade cable is shown below.
Figure 15
Cascade cable connection
Power synchronized unit#0
Power synchronized unit#1
When the power synchronized units are cascaded, the unit that is connected to the server UPS unit is "power
synchronized unit#0".
Do not attach a branch connector or a termination resistor to the CASCADE port or the AC SENSOR port. Doing
so makes operations unstable.
CAUTION
FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide (Power Synchronized Unit)
Server#0
UPS unit for
Server#0
CASCADE port
Cascade cable
(optional)
Do
When connecting external (signal, power, etc.) cables, avoid placing stress on
them. Not doing so may damage the cables.
Do Not
Do not forcibly bend or fold the cable. Doing so may damage the cable and cause
the power synchronized unit to malfunction.
90
Do not bend
more than 90 degrees
51
Copyright 2019 FUJITSU LIMITED
Server#1
Power cord (for AC sensor)
SENSOR ports
AC SENSOR port
Do not fold
UPS unit for
Server#1
P3AM-8012-14ENZ0