4.
Connection and Settings
Setting the ETERNUS DX/AF
Connection SVC
Select the SVCs (SVC#0 and/or SVC#1) of the ETERNUS DX900 S5, ETERNUS DX8900 S4, or ETERNUS DX8700 S3/
DX8900 S3 that are connected to the power synchronized unit with the RS232C cable.
Select "SVC#0" when the power synchronized unit is connected to the PWC port on SVC#0. Select "SVC#1" when
the power synchronized unit is connected to the PWC port on SVC#1.
When different power synchronized units are connected to SVC#0 and SVC#1 in a duplicated configuration,
select both "SVC#0" and "SVC#1".
Delay until Shutdown
Do not change the default setting (0 minute).
Set management unit interface
Select "Power Synchronized Unit".
Power Failure Signal
"Positive" (positive logic) is automatically set.
Low Battery Signal
"Negative" (negative logic) is automatically set.
UPS Shutdown Signal
Do not select the "Enable" checkbox.
"Positive" (positive logic) is set by default.
■ ETERNUS DX80 S2/DX90 S2
This section explains the setting items on the power synchronization setting screen for the ETERNUS DX80 S2/
DX90 S2.
Figure 13
ETERNUS DX80 S2/DX90 S2 setup (Setup Power Management screen)
FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide (Power Synchronized Unit)
46
Copyright 2019 FUJITSU LIMITED
P3AM-8012-14ENZ0