3 heating and 2 cooling with automatic humidity control and dual fuel switch, outdoor wireless temperature transmitter and receiver kit
Table of Contents

Advertisement

ADVANCED SETTINGS - DIFFERENTIAL SETTINGS

> >
PUREPRO
TM
DP732T allows you to control up to 3 Stages of Heating and 2 Stages of Cooling,
dependent on the type of system you have configured.
• 1ST STAGE DIFFERENTIAL: Set temperature difference between temperature set point and
actual temperature reading before 1st stage heating or cooling is initiated.
• 2ND STAGE DIFFERENTIAL: Set temperature difference between 1st stage initiation and 2nd stage
heating or cooling initiation.
• 3RD STAGE DIFFERENTIAL: Set temperature difference between 2nd stage initiation and 3rd stage
heating or cooling initiation.
• OB ENERGIZED: Reverses the Heat Pump OB Valve contact to HEAT or COOL (manufacturer
dependent).