7-DAY PROGRAMMABLE TOUCHSCREEN THERMOSTAT
(FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS)
I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S
• Please read all of these instructions carefully before beginning
installation.
• Label every wire terminal designation on your existing thermostat
wiring before removing your old thermostat.
• Ignore the color of the wires since they may not comply with any
standard. Please connect wires using the terminal letter
designations.
Thank you for your confidence in our product. To obtain the best results
from your investment, please read and follow the installation procedures
carefully, and one step at a time. This will save you time and minimize the
chance of damaging either the thermostat or possibly your heating and
cooling system. These instructions may contain information beyond that
which may be required for your particular installation.
SYSTEM COMPATIBILITY . . . . . . . . . 2
FEATURES . . . . . . . . . . . . . . . . . . . 3
TOOLS YOU MAY NEED . . . . . . . . . . . 3
MOUNTING LOCATION . . . . . . . . . . . 4
REMOVE OLD THERMOSTAT . . . . . . . 4
INSTALL THERMOSTAT BASE . . . . . . . 5
WIRING INFORMATION . . . . . . . . . . . 6
WIRING DIAGRAMS . . . . . . . . . . . . . 8
HARDWARE SETUP OPTIONS . . . . . . 17
WARNING: Use Energizer
Energizer
DURACELL
© 2011 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
T X 9 6 0 0 T S
SMART TEMP
IMPORTANT!
®
or DURACELL
®
is a registered trademark of Eveready Battery Company, Inc.
®
is a registered trademark of The Gillette Company, Inc.
®
UNIVERSAL
COMPLETE THE INSTALL . . . . . . . . . 19
FRONT PANEL ITEMS . . . . . . . . . . . 19
OPERATING INSTRUCTIONS . . . . . . . 20
TEMPERATURE PROGRAMS . . . . . . . 23
ADVANCED FEATURES . . . . . . . . . . 24
BATTERY REPLACEMENT . . . . . . . . . 32
TECHNICAL ASSISTANCE . . . . . . . . . 33
LIMITED WARRANTY . . . . . . . . . . . 33
MERCURY NOTICE . . . . . . . . . . . . . 33
®
Alkaline Batteries Only.
52106

Advertisement

Table of Contents
loading

Summary of Contents for Lux Products SMART TEMP TX9600TS

  • Page 1: Table Of Contents

    WARNING: Use Energizer ® or DURACELL ® Alkaline Batteries Only. Energizer ® is a registered trademark of Eveready Battery Company, Inc. DURACELL ® is a registered trademark of The Gillette Company, Inc. © 2011 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED...
  • Page 2: System Compatibility

    TX9600TS Mode Switch Menu Button MENU AUTO ˚ ˚ HEAT Clock COOL System Mode Switch Room Temperature Set Temperature SYSTEM COMPATIBILITY: The electrical rating for this thermostat is 1.5 Amps per terminal, with a maximum total combined load of 3.0A for all terminals combined. COMPATIBLE WITH: •...
  • Page 3: Features

    FEATURES: • 1 or 2-Heat / 1-Cool, 7-day programming • Universal Compatibility for all system types • Each day of the week can be programmed separately • Easy to use, touchscreen menu operation • User-selectable periods per day (2 or 4) •...
  • Page 4: Mounting Location

    MOUNTING LOCATION: On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, please follow these general guidelines: 1. Mount the thermostat on an inside wall, about 5 ft. (1.5m) above the floor. 2.
  • Page 5: Install Thermostat Base

    INSTALL THERMOSTAT BASE: Large Indentation: Front Housing Release Mode Switches THERMOSTAT TOP VIEW 1. Strip wire insulation leaving only 3/8 in. (9.5mm) bare wire ends, and clean off any corrosion present. 2. Fill the wall opening with non-combustible insulation to prevent drafts from affecting the thermostat’s normal operation.
  • Page 6: Wiring Information

    WIRING INFORMATION: CONNECTING THE WIRES: When attaching the wires to the thermostat, please ensure that the bare wire ends are held ALL the way into the terminal block while the screw is being tightened. WIRING BASE PLATE NOTICE: This thermostat model is part of a family of similar models that have the same general visual appearance.
  • Page 7 WIRING DIAGRAM NOTES: (Important, please read all notes before connecting wires) • If the information provided in the following wiring diagrams does not clearly represent or match your system, please refer to the “TECHNICAL ASSISTANCE” section of this manual, and contact us before removing any of your existing thermostat wiring.
  • Page 8: Wiring Diagrams

    WIRING DIAGRAMS: DIAGRAM SYSTEM TYPE / DESCRIPTION PAGE # CONVENTIONAL: HEATING ..........8 1-STAGE OR 2-STAGE 2, 3, 4, 5 WIRES CONVENTIONAL: HEATING ..........9 3-WIRE ZONE VALVE 3, 4 WIRES CONVENTIONAL: COOLING..........10 1-STAGE 3, 4 WIRES CONVENTIONAL: HEATING AND COOLING ......11 1-STAGE HEAT 4, 5 WIRES CONVENTIONAL:...
  • Page 9 1-STAGE OR 2-STAGE, HEATING ONLY 2, 3, 4, 5 WIRES (INCLUDING MILLIVOLT) (2-WIRE HEAT USE “RH” & “W1”) Factory RH-RC Jumper Wire Installed FAN WIRE MAY NOT BE PRESENT IN ALL SYSTEMS SYSTEM COMMON STAGE STAGE SYSTEM 24V TRANSFORMER HEATER NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC...
  • Page 10 HOT WATER HEATING ONLY 3, 4 WIRES (WITH A 3-WIRE ZONE VALVE) Factory RH-RC Jumper Wire Installed SYSTEM COMMON CLOSE OPEN SYSTEM 24V TRANSFORMER 3-WIRE ZONE VALVE OPEN = Heat On CLOSE = Heat Off NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC...
  • Page 11 3, 4 WIRES 1-STAGE, COOLING ONLY Factory RH-RC Jumper Wire Installed SYSTEM COMMON SYSTEM 24V TRANSFORMER CONDITIONER NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC...
  • Page 12 CONVENTIONAL (NON HEAT PUMP) 4, 5 WIRES 1-STAGE HEATING AND 1-STAGE COOLING Factory RH-RC Jumper Wire Installed SYSTEM COMMON SYSTEM 24V HEATER CONDITIONER TRANSFORMER NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC...
  • Page 13 CONVENTIONAL (NON HEAT PUMP) 5, 6 WIRES 2-STAGE HEATING AND 1-STAGE COOLING Factory RH-RC Jumper Wire Installed SYSTEM COMMON STAGE STAGE SYSTEM 24V CONDITIONER TRANSFORMER HEATER NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC...
  • Page 14 1-STAGE HEATING AND 1-STAGE COOLING 5, 6 WIRES WITH TWO SEPARATE 24V TRANSFORMERS Factory RH-RC Jumper Wire REMOVED SYSTEM COMMON COOL 24V HEAT 24V HEATER CONDITIONER TRANSFORMER TRANSFORMER NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC...
  • Page 15 SINGLE-STAGE HEAT PUMP SYSTEM 4, 5 WIRES WITH NO AUX OR EMERGENCY HEAT ** Use “O” or “B” CUSTOMER INSTALLED Y-W1 Jumper Wire Terminals, Never Both Factory RH-RC Jumper Wire Installed SYSTEM COMMON REVERSING SYSTEM 24V HEAT PUMP VALVE TRANSFORMER NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC...
  • Page 16 2-HEAT / 1-COOL, HEAT PUMP SYSTEM 5, 6 WIRES WITH AUX AND EMERGENCY HEAT ** Use “O” or “B” CUSTOMER INSTALLED Y-W1 Jumper Wire Terminals, Never Both Factory RH-RC Jumper Wire Installed SYSTEM COMMON REVERSING SYSTEM 24V AUX / EMERG. HEAT PUMP VALVE TRANSFORMER...
  • Page 17: Hardware Setup Options

    HARDWARE SETUP OPTIONS: On the thermostat’s circuit board, there is a row of DIP switches, labeled #1 through #8. The position of these switches will change how the thermostat operates, and also how information is conveyed to you on the LCD display screen.
  • Page 18 SWITCH #4 (SCALE): [OFF/RIGHT = F, default] All temperature values are displayed using the Fahrenheit scale. [ON/LEFT = C] This setting displays all temperature values using the Celsius scale. SWITCH #5 (TIME): [OFF/RIGHT = 12 HR, default] This setting displays the clock times and temperature program period start time values on the screen using US standard AM and PM values.
  • Page 19: Complete The Install

    GAS / ELEC SLIDE SWITCH (FAN OPERATION): This switch is a physical component by itself on the circuit board, and is much larger than the DIP switches listed above. [DOWN = GAS, BATTERY default] This setting lets the heating system control the blower fan automatically by itself.
  • Page 20: Operating Instructions

    NOTE: The Fan Mode switch only works if your system provides a wire for the thermostat’s “G” wire terminal, to control a blower fan. The Fan Mode switch has no effect in systems that do not have a blower fan (such as a hot water radiator system).
  • Page 21 PERIOD HEAT MODE COOL MODE 6:00 AM 70 °F (21 °C) 6:00 AM 78 °F (26 °C) MORN 8:00 AM 62 °F (17 °C) 8:00 AM 82 °F (28 °C) 6:00 PM 70 °F (21 °C) 6:00 PM 78 °F (26 °C) 10:00 PM 62 °F (17 °C) 10:00 PM 75 °F (24 °C) NITE...
  • Page 22 LCD DISPLAY BACKLIGHT: The display screen is lighted to assist viewing at nighttime, or in locations with low light levels. A press of any area on the touch panel will light the display for approximately 10 seconds. Any screen presses that occur while the light is on will reset the 10-second timer, causing the screen to remain illuminated for an additional 10 seconds.
  • Page 23: Temperature Programs

    STATIC NOTICE: This thermostat is protected against normal static electric discharges, however to minimize the risk of damaging the unit in extremely dry weather, please touch a grounded metal object before touching your thermostat. TEMPERATURE PROGRAMS: By default, this thermostat has 4 separate program periods for both Heat and Cool mode, they are: MORN, DAY, EVE, and NITE.
  • Page 24: Advanced Features

    words “COPY PROGRAM” will flash briefly at the top of the screen, followed by “FROM” and “TO”. Under the word “FROM” will be a flashing day of the week. Using the UP and DOWN buttons, select the day that you want to copy from.
  • Page 25 from 0°F to 9°F degrees (0°C to 5°C degrees). When set to 0 degrees, the second heating stage is completely disabled while in regular Heat mode (Emergency Heat mode will still function for heat pump configurations). The Offset value will determine the number of degrees from the set point that will be required for the second heating stage to turn on.
  • Page 26: Temperature Calibration

    TEMPERATURE CALIBRATION DESCRIPTION: The internal temperature sensor in this thermostat is accurately calibrated at the factory, and in most cases, alterations to this setting should not be needed. The Temperature Calibration feature allows you to manually offset the measured temperature by as much as plus or minus 5°F (3°C) degrees from its original value.
  • Page 27 will be 5F (3C) degrees lower than the current set temp. For Cool mode, the set temperature used will be 5F (3C) degrees higher than the current set temp. NOTE: The Setback settings need to be performed in a timely manner, as the thermostat will timeout and automatically exit these adjustment screens after approximately 10 seconds without a button press.
  • Page 28 NOTE: The Temperature Limit Stop settings need to be performed in a timely manner, as the thermostat will timeout and automatically exit the setting screens after approximately 10 seconds without a button press. The following examples are shown for setting the maximum set temperature for Heat mode.
  • Page 29 KEYPAD LOCKOUT: You can lock the touch-panel buttons to prevent unauthorized tampering of your thermostat settings. NOTE: These keypad lock instructions need to be performed in a timely manner, as the thermostat will timeout and automatically exit the keypad lock screens and return to the Normal Run screen after approximately 10 seconds without a button press.
  • Page 30 The Air Filter Monitor counts the duration of filter usage that has occurred, since the last time the Filter Monitor has been reset. This feature is for information purposes only, and does not affect the operation of your heating or cooling equipment, or the thermostat. When the filter usage duration has expired, the words “CHANGE FILTER”...
  • Page 31: Hardware Reset

    examples are shown for viewing the Energy Usage while in Heat mode. Viewing the Cool mode information is done in the same exact manner in Cool mode. TO VIEW THE ENERGY USAGE TIMERS: Press the MENU button, then press the SCROLL button until “REVIEW HEAT ENERGY USAGE” is shown, then press the OK button.
  • Page 32: Battery Replacement

    Reset, press and hold the Software Reset button for at least 5 seconds. The LCD display screen will become fully populated, then return to normal. The thermostat will still retain the current day and time even after a Software Reset has been performed. COMPRESSOR PROTECTION BYPASS: This optional feature permits the installer or service technician to temporarily disable the built in compressor protection delays.
  • Page 33: Technical Assistance

    TECHNICAL ASSISTANCE: If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please contact our Technical Assistance department at 856-234-8803 during regular business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday through Friday.
  • Page 34 MENU AUTO ˚ ˚ HEAT COOL Mt. Laurel, New Jersey 08054, USA http://www.luxproducts.com 856-234-8803...

Table of Contents