Electrolux EFTD052E Installation Manual page 38

Flight type dishwasher
Table of Contents

Advertisement

If the water pressure is:
• more than600 kPa [6 bar], a pressure reducing valve must
be installed on the inlet pipe. The supply water temperature
is related to the machine setup;
• is less than 100 kPa [1 bar], a booster pump must be
installed ahead of the machine.
Water connection ISO 228/1 DN 20 (G3/4")
• Cold water inlet temperature for model with ESD:
– 10-30℃
– The recommended cold water temperature is: 10℃
• Cold water inlet temperature for model without ESD:
– 10-65℃
• Hot water inlet temperature:
– 50-65℃
– The recommended hot water temperature is: 50℃
• Water inlet pressure:
– 100 kPa [1 bar] - 600 kPa [6 bar]
CAUTION
For every connection, installing a cut-off
valve "B" and a pressure gauge "A"
between the machine and the mains.
Pay attention to seal every component in
order to avoid any water leaks.
NOTE!
Connection pipes with anti-return/back flow protec-
tion and check valve and on/off valve are available
as optional accessories.
To ensure efficient machine operation, install a
water treatment device on the dishwasher inlet
connection piping if:
• the water hardness exceeds 14°fH/8°dH/10°eH
(a water softener and/or a water demineralizer);
• the water concentration of chlorides in water
exceeds 20 ppm (a reverse osmosis device).
38
Drain outlet hose connection
• Connect the drain outlet hose to the main drain pipe, fitting a
trap, or place the outlet pipe over an "S" trap set into the
floor.
B
B
A
A