Section 11: Reporting; Receivers Compatible With The Control Panel - Honeywell Farenhyt Series Manual

Addressable fire alarm control panel
Hide thumbs Also See for Farenhyt Series:
Table of Contents

Advertisement

This section lists receivers that are compatible with this control panel, and the reporting codes sent by the control panel for SIA and Contact
ID formats.

11.1 Receivers Compatible with the Control Panel

Table 11.1 lists receivers compatible with the control panel.
Manufacturer
Silent Knight by Honeywell
Honeywell Security
Ademco
Ademco
Sur-Gard
Osborne Hoffman
Event Description
System Events
AC power low trouble
AC power low trouble restore
Auto dialer test communications trouble line
1
Auto dialer test communications trouble line
1 restore
Auto dialer test communications trouble line
2
Auto dialer test communications trouble line
2 restore
Automatic test normal
Automatic test off normal
Battery voltage trouble
Battery voltage trouble restore
Date changed event
ECS Reset
Emergency System Overridden
Emergency System Overridden Restore
Fire drill has begun
Fire drill has ended
F1 Mapping Inhibited
F1 Mapping Inhibited Restoral
F2 Mapping Inhibited
F2 Mapping Inhibited Restoral
F3 Mapping Inhibited
F3 Mapping Inhibited Restoral
F4 Mapping Inhibited
IFP-300 Series Manual — P/N LS10145-001SK-E:C 4/6/2022

Section 11: Reporting

Model
Model 9800
Model 9000 (SIA formats)
AlarmNet 7810-ir
MX8000
Model 685 (Contact ID )
SG-MLR2-DG (V. 1.64 or higher)
Quickalert
Table 11.1 Receivers Compatible with the Control Panel
SIA Reporting Format
SIA pi Modifier
Module
SIA
Parameter
ID #
Event
(If Any)
Code
s
System Events are reported when either "Report by Point" or Report by Zone is selected
AT
0
AR
0
YC
1
YK
1
YC
2
YK
2
RP
0
RY
0
YT
Exp. ID
YR
Exp. ID
JD
0
OR
1
QS
0
QR
0
FI
0
FK
0
FT
2001
FJ
2001
FT
2002
FJ
2002
FT
2003
FJ
2003
FT
2004
Table 11.2 Report Formats Table
Format
SIA and Contact ID
SIA
IP and Cellular Receiver, Contact ID only
SIA and Contact ID
Contact ID
SIA and Contact ID
SIA and Contact ID
Contact ID Reporting Format
SIA
Fixed Length
Qualifier Event
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
ATNN000000
1
ARNN000000
3
YCNN000001
1
YKNN000001
3
YCNN000002
1
YKNN000002
3
RPNN000000
1
RYNN000000
1
YTNNXX0000
1
YRNNXX0000
3
JDNN000000
1
ORNN000001
1
QSNN000000
1
QRNN000000
3
FINN000000
1
FKNN000000
3
FTNN002001
1
FJNN002001
3
FTNN002002
1
FJNN002002
3
FTNN002003
1
FJNN002003
3
FTNN002004
1
Group #
Contact #
Code
301
00
000
301
00
000
350
Receiver # 001
350
Receiver # 001
350
Receiver # 002
350
Receiver # 002
602
00
000
608
00
000
302
Exp. ID
000
302
Exp. ID
000
625
00
000
401
00
001
244
00
000
244
00
000
604
00
000
604
00
000
570
00
001
570
00
001
570
00
002
570
00
002
570
00
003
570
00
003
570
00
004
145

Advertisement

Table of Contents
loading

Table of Contents