External Detector orrection, Adjustment #103
his procedure shows you how to generate correction constants for the receiver to make
external detector or internal broadband measurements. Perform this test whether or not you
plan to use external detectors.
In this test, an accurate
equired Equipment
Equipment
escription
Voltage reference source
1
See Note below.
1
Note
If a voltage reference source is not available, connect the requested voltages
to the external detector connector as shown in Figure 2-8. Note that both a
positive and negative voltage are required simultaneously, and both must be
referenced to ground.
pin D = V+
pin C = V
pin K = GND
hese voltages may be obtained from a dual power supply, however it is
possible to derive the required voltages from the external detector connector
itself.
pin B =
pin A = +15 with respect to GND (pin K)
Insert artwork here.
6
0.5 V is provided to both the X and Y detector inputs.
(part of service kit)
0
0
15 V with respect to GND (pin K)
Figure 2-8. External Detector Connector, Front View