Mounting And Cooling; 4-Channel Amplifier Rear Panel - K-array Kommander-KA User Manual

2ru digital processing multi-channel amplifiers
Table of Contents

Advertisement

Kommander-KA
User Guide

Mounting and cooling

K-array Kommander amplifiers are provided with a couple of
brackets for common 19" rack installation: each Kommander
amplifier occupies 2 rack units. In order to set the amplifier for
rack installation:
• unscrew the four bottom feet;
• assemble the lateral rack mounting brackets with screws
provided within the package.
In order to prevent any mechanical issue, use both frontal and
rear mounting brackets to secure the amplifier to its location.
Install the amplifier in a well-ventilated location at 35°C (95°F)
max environment temperature.
The ventilation openings must not be impeded by any item.
Fresh air enter the amplifier from aside, warm air is expelled
under the front panel.
Fresh air
In rack mount installation leave one rack unit empty every three
installed amplifiers to guarantee adequate air flow.
10

4-channel Amplifier Rear Panel

1 2
1. Status LED
2. Reset button
3. 4x XLR-F balanced line channel inputs
4. USB ports
5. 2x PC 4/ 4-ST-7,62 speaker output terminals
6. PowerCon TRUE link (AC mains out)
7. PowerCon TRUE inlet (AC mains in)
8. QR Code for the K-array Connect app remote connection
9. RJ45 Ethernet port
10. 4x XLR-M balanced line channel outputs
8-channel Amplifier Rear Panel
A B
A. Status LED
B. Reset button
C. 4x XLR-F balanced line channel 1, 2, 3 and 4 inputs
D. USB ports
Warm air
E. 4x PC 4/ 4-ST-7,62 speaker output terminals
F. PowerCon TRUE link (AC mains out)
G. PowerCon TRUE inlet (AC mains in)
H. QR Code for the K-array Connect app remote connection
I.
J. 4x XLR-M balanced line channel 5, 6, 7 and 8 inputs
3
4
5
10
9
C
D
E
J
I
RJ45 Ethernet port
6 7
8
F G
H

Advertisement