HP StorageWorks vs80 User Manual page 67

1/8 autoloader
Table of Contents

Advertisement

Table 5
Error Codes
Error Code
3 0 83
Inventory not valid.
3 0 84
Source empty.
3 0 85
Destination full.
3 0 86
Mail slot access rejected.
3 0 87
Operation timeout.
3 0 88
Communications error during
loop-back.
3 0 89
System test timeout.
Recovered loader error.
3 0 8F
3 0 90
Mechanical Initialization failure.
3 0 91
Inventory scan failure.
3 0 92
Preposition failed.
3 0 93
Cartridge load error.
Chapter 4
Description
Details
The cartridge inventory is not valid because of
manual changes or previous fatal errors. Update
the inventory using the Re-inventory option in the
Configuration menu. See
cycle.
There is no cartridge in the location where a
cartridge move was issued.
The location where a cartridge move was issued
already contains a cartridge.
User attempted to access the mail slot, but media
removal was prevented by the host.
A command did not complete in the required
amount of time.
Cycle power on the autoloader and attempt the
operation again. If the error recurs, contact your
technical support representative.
There was a communication timeout between the
drive and loader during the System Test.
Loader error recovery successful. Your diagnostic
tool can provide details of the original loader
error.
The robotics were not able to move to the safe
mechanical initialization position. Manual
intervention is necessary.
Fatal robotic error occurred during the inventory
scan.
Belt positioning error occurred during
'Preposition' command.
A failure occurred while trying to load a
cartridge from the drive to its slot.
Diagnostics and Troubleshooting
page 38