Note
If the cartridge is not a valid code update cartridge, the LCD will
temporarily display error code "BC," the autoloader will reset,
the cartridge will be exported, and the LCD will display Bad
upgrade tape.
7.
During the firmware update, which can take several minutes, the LCD
screen displays CODE UPDATE IN PROGRESS. When firmware update is
complete, the autoloader resets, then unloads and exports the code
update cartridge. When the LCD screen prompts you, remove the code
update cartridge and press the [Enter] button to close the door.
8. If you exported a data cartridge to make room for the code update
cartridge, be sure to import the cartridge to its original slot. See
Cartridges
on page 30 for instructions.
Note
After a firmware update, the firmware revision displayed on the
LCD will not be updated until the autoloader is power cycled.