18.2
TTL Communication:SV output and RATE function
Open RATE function (use for slave controller)
Display AL3 :SET2.1=1
Display ALD3:SET4.1=1
Display RATE(AL3 will be replaced) :SET0.2=1
Set ALD3 to 0. (In Level 3)
Slave SV = ( RATE ÷9999)×master SV
Example :
PFY900
Master
SV OUT (SET0.1=1)
IDNO=0 (SET5.4=1)
BAUD=2400(SET5.4=1)
Master
1000
SV
1 hour
SV_1=1000
TM_1=01:00
OUT_1=100%
( Three controllers reach to the max value at the same time )
All manuals and user guides at all-guides.com
Connection Diagram
FY900
Slave 1
IDNO=1 (SET5.4=1)
BAUD=2400
(SET5.4=1)
open RATE function
Time Chart
Slave 1
900
SV
Time
1 hour
RATE = 9000
SV=900
53
FY900
Slave 2
IDNO=1 (SET5.4=1)
BAUD=2400
(SET5.4=1)
open RATE function
Slave 2
800
SV
Time
1 hour
RATE =8000
SV=800
Time