Technical specifications
Ambient temperature
Relative humidity
Housing, dimensions and weight
Design
Housing material
Degree of protection
Dimensions (W x H x D)
Weight
Installation options
Mounting restriction
Conformal coating of the PCBs
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
Wiring rules
1)
Note the wiring rules (Page 58).
Derating
2)
The derating values depend on the maximum ambient temperatures during operation up to
2000 m.
SCALANCE XC-300
Operating Instructions, 10/2022, C79000-G8976-C584-01
Property
With operation up to 2000 m above
sea level
With operation between 2000 m
and 3000 m above sea level
With operation between 3000 m
and 4000 m above sea level
During storage
During transportation
During operation at 25 ℃
compact
Basic housing
Front cover
IP20
210 x 147 x 125 mm
2040 g
Wall mounting
Installation on a DIN rail
Mounting on an S7-300 standard rail
Mounting on an S7-1500 standard rail
Observe mounting positions (Page 44)
No
11.6 years
9.4 Technical specifications of SCALANCE XC332
Startup at -40 °C
During operation in horizontal installation posi‐
tion (position 1):
-40 °C to +60 °C
During operation in a different installation posi‐
tion (positions 2, 3 and 4):
-40 °C ... +50 °C
The high value of the temperature range is re‐
duced by 5 °C
2)
.
The high value of the temperature range is re‐
duced by 10 °C
.
2)
-40 °C to +85 °C
-40 °C to +85 °C
≤ 95% without condensation
Die cast aluminum, powder coated
Polycarbonate (PC-GF10)
Technical specifications