Technical specifications
Ambient temperature
2)
SCALANCE XC-300
Operating Instructions, 10/2022, C79000-G8976-C584-01
Property
With LAN operation with RJ45 plug
Up to 2000 m above sea level
When operating with plug-in trans‐
ceivers of the types:
•
SFP992-1
•
SFP992-1LD
•
SFP992-1LD (C)
Up to 2000 m above sea level
When operating with plug-in trans‐
ceivers of the types
:
3)
•
SFP992-1+
•
SFP992-1LD+
•
SFP992-1LH
•
SFP992-1LH+
•
SFP992-1ELH
•
SFP992-1BXMT
•
SFP992-1BXMR
•
SFP992-1BX10T
•
SFP992-1BX10R
Up to 2000 m above sea level
When operating with plug-in trans‐
ceivers of the types:
•
SFP993-1
•
SFP993-1LD
Up to 2000 m above sea level
When operating with SFP transceiv‐
ers of the type
3)
:
•
SFP993-1LH
Up to 2000 m above sea level
With operation between 2000 m
and 3000 m above sea level
With operation between 3000 m
and 4000 m above sea level
During storage
9.2 Technical specifications of SCALANCE XC319-4
Startup at -40 °C
During operation in horizontal installation posi‐
tion (position 1):
-40 °C to +60 °C
During operation in a different installation posi‐
tion (positions 2, 3 and 4):
-40 °C ... +50 °C
During operation in horizontal installation posi‐
tion (position 1):
-40 °C to +60 °C
During operation in a different installation posi‐
tion (positions 2, 3 and 4):
-40 °C ... +50 °C
During operation in horizontal installation posi‐
tion (position 1):
-40 °C to +55 °C
During operation with vertical mounting posi‐
tion (position 2) or with ceiling mounting / face
down (position 3):
-40 °C ... +50 °C
During operation with floor installation / face up
(position 4):
-40 °C ... +40 °C
During operation in horizontal installation posi‐
tion (position 1):
-40 °C to +55 °C
During operation with vertical mounting posi‐
tion (position 2) or with ceiling mounting / face
down (position 3):
-40 °C ... +50 °C
During operation with floor installation / face up
(position 4):
-40 °C ... +40 °C
During operation in horizontal installation posi‐
tion (position 1):
-40 °C ... +40 °C
The maximum ambient temperature is reduced
by 5 °C
4)
The maximum ambient temperature is reduced
by 10 °C
4)
-40 °C to +85 °C
Technical specifications