Accuracy

Accuracy is specified for 1 year after calibration at operating temperatures of 18
relative humidity a 0 % to 75 %. Accuracy specifications take the form of:
± ([% of Reading] + [Number of Least Significant Digits]).
Function
AC Volts
K
(45 Hz to 400 Hz)
Voltage Frequency
(HZ)
1 Hz to 99.99 kHz
Threshold 10.0 V
DC Volts
L
Ω
Resistance
Continuity
Threshold: 30 Ω
Capacitance
E
Diode
G
AC Current A
?
(45 Hz to 400 Hz)
AAC Frequency (Hz)
Threshold 10.00A
DC Current
[1]
A
[1] After zero operation.
[2] <1 % range, unspecified.
Range
Resolution
600.0 V
0.1 V
9.999 Hz
0.001 Hz
99.99 Hz
0.01 Hz
999.9 Hz
0.1 Hz
9.999 kHz
0.001 kHz
99.99 kHz
0.01 kHz
600.0 V
0.1 V
600.0 Ω
0.1 Ω
6.000 kΩ
0.001 kΩ
60.0 kΩ
0.01 kΩ
9.999 μF
0.001 μF
99.99 μF
0.01 μF
999.9 μF
0.1 μF
3.000 V
0.001 V
0.01 A
40.00 A
[2]
400.0 A
0.1 A
0.01 A
60.00 A
[2]
600.0 A
0.1 A
1000 A
1 A
45.0 Hz to
0.1 Hz
400.0 Hz
0.01A
60.00 A
[2]
600.00 A
0.1 A
1000 A
1 A
Accuracy
301A
301B
1.5 %+5
0.1 %+3
1 %+5
1 %+5
2 %+5
5 %+5
5 %+5
10 %
2 %+10 NA
NA
2 %+5
NA
NA
NA
2 %+10 2 %+10 2 %+10 2 %+10
NA
2 %+5
2 %+5
NA
NA
2 %+5
0.1 %+3
NA
NA
NA
NA
NA
NA
NA
NA
NA
Clamp Meter
Specifications
C to 28
°
301C
301D
301E
NA
NA
NA
NA
2 %+5
2 %+5
NA
2 %+5
2 % +10
2 % +5
NA
2 % +5
C,
°
3