Fluke 317 User Manual

Fluke 317 User Manual

Clamp meter
Hide thumbs Also See for 317:

Advertisement

317/319
Clamp Meter
Users Manual
PN 4092877
September 2011
© 2011 Fluke Corporation. All rights reserved. Specifications subject to change without
notice. All product names are trademarks of their respective companies.

Advertisement

Table of Contents
loading

Summary of Contents for Fluke 317

  • Page 1 317/319 Clamp Meter Users Manual PN 4092877 September 2011 © 2011 Fluke Corporation. All rights reserved. Specifications subject to change without notice. All product names are trademarks of their respective companies.
  • Page 2 LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.
  • Page 3: Table Of Contents

    Table of Contents Title Page Introduction ............1 How to Contact Fluke ..........1 Safety Information ..........2 Symbols ..............5 Specifications ............6 General Specifications ........6 Electrical Specifications ........7 Software Specifications ........10 Environmental Specifications......10 The Product............11...
  • Page 4 317/319 Users Manual...
  • Page 5: Introduction

    Clamp Meter Introduction The Fluke 317 and 319 are hand-held, battery-operated clamp meters (the Product) that measure: • ac and dc current • ac and dc voltage • resistance • continuity • frequency The Product ships with: • test leads •...
  • Page 6: Safety Information

    317/319 Users Manual Or, visit Fluke’s website at www.fluke.com. To register your product, visit http://register.fluke.com. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. Safety Information XWarning To prevent possible electrical shock, fire, or personal injury: • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Page 7 Clamp Meter Safety Information • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground. • Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and flame-resistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed.
  • Page 8 317/319 Users Manual • Do not use test leads if they are damaged. Examine the test leads for damaged insulation, exposed metal, or if the wear indicator shows. Check test lead continuity. • Disconnect power and discharge all high-voltage capacitors before you measure resistance, continuity, capacitance, or a diode junction.
  • Page 9: Symbols

    Direct current  Do not dispose of this product as unsorted municipal  waste. Go to Fluke’s website for recycling information. Conforms to relevant European Union directives.  Equipment is designed to protect against transients in equipment in fixed equipment installations, such as...
  • Page 10: Specifications

    317/319 Users Manual Specifications General Specifications Digital Display ......6000 count resolution Low Battery Indication .... Shows  when the batteries are below their required voltage Power Source ......Three AAA IEC LR03 batteries Clamp Opening Size....37 mm (1.45 in) Jaw Diameter ......
  • Page 11: Electrical Specifications

    Clamp Meter Specifications Electrical Specifications The accuracy specification is defined as ±(% reading + digits) at 23 °C ± 5 °C. Function Parameter Range 40.00 A 40.00 A 600.0 A 600.0 A 1000 A Resolution 0.01 A 0.01 A 0.1 A 0.1 A Accuracy 1.6 % ±6 digit...
  • Page 12 317/319 Users Manual Function Parameter Range 40.00 A 40.00 A 600.0 A 600.0 A 1000 A Resolution 0.01 A 0.01 A  0.1 A 0.1 A (A dc) Accuracy 1.6 % ±6 digit 1.6 % ±6 digit [40 A] [40 A] 1.5 % ±5 digit...
  • Page 13 Clamp Meter Specifications Function Parameter Range 5.0 - 500.0 Hz Accuracy 0.5 % ±5 digit 10 – 100 Hz ≥5 A, 5 – 10 Hz, Trigger Level 100 – 500 Hz ≥10 A The accuracy specifications apply at 23 °C ± 5 °C (73 °F ±41 °F) Below 18 °C and above 28 °C (64 °F and above 82 °F) accuracy degrades at (0.1) times specification per °C.
  • Page 14: Software Specifications

    317/319 Users Manual Software Specifications Calibration ......Full manual calibration and test One-year calibration cycle Data Integrity and Security ..Calibration parameters stored in flash ROM. Environmental Specifications Operating Temperature ... -10 °C to 50 °C (14 °F to 122 °F) Storage Temperature ....
  • Page 15: The Product

    Clamp Meter The Product The Product ClampMeter 600 V 1000 A 1000 A Tactile Barrier 600 A 40 A HOLD MAXMINAVG ACDC ZERO INRUSH TRUE RMS CLAMP METER 600 V etr111.eps...
  • Page 16 317/319 Users Manual Jaw Wear Jaw Wear Indicator 600 V 1000 A 1000 A 600 A 40 A 1000 A 600 A 40 A HOLD ZERO INRUSH TRUE RMS CLAMP METER ZERO 600 V etr113.eps...
  • Page 17 Clamp Meter The Product 1000 A 600 A 40 A HOLD ZERO INRUSH TRUE RMS CLAMP METER 600 V ZERO etr114.eps...
  • Page 18 317/319 Users Manual 40 A HOLD ZERO INRUSH TRUE RMS CLAMP METER 600 V <30 1000 A 600 A 40 A etr116.eps...
  • Page 19 Clamp Meter The Product 7 Display Hold 1000 A 600 A HOLD 40 A HOLD 8 MIN MAX AVG 1000 A 600 A 40 A HOLD ZERO INRUSH 2 sec = Exit etr122.eps...
  • Page 20 317/319 Users Manual 600 V 1000 A 1000 A 600 A 40 A HOLD 600 V 1000 A 1000 A 600 A ZERO INRUSH 40 A TRUE RMS CLAMP METER 600 V HOLD ZERO INRUSH TRUE RMS CLAMP METER 600 V...
  • Page 21 Clamp Meter The Product etr123.eps...
  • Page 22 317/319 Users Manual...

This manual is also suitable for:

319

Table of Contents