Specifications
General Specifications
Cable length: 4 m (0.15 in)
Length of measuring head: 92 cm (36 in)
Flexible Current Probe Diameter: 8 mm (0.3 in)
Operating temperature range: -10 °C to +70 °C
(14 °F to 158 °F)
Storage temperature range: -20 °C to +80 °C
(-4 °F to 198 °F)
Operating humidity (non-condensing): 10 % to 80 % rh
Altitude: max. 2000 m (6,562 ft)
Weight: 1.2 kg (0.55 lb)
Reference Conditions
Environment temperature range: +18 °C to +26 °C
(64.4 °F to 78.8 °F)
Humidity: 20 to 75 % rh
Current: nominal value In, sinusoidal waveform, 48 Hz to
65 Hz, distortion factor: <1 %, no DC component, stray field
<40 A/m, conductor centered within the Probe.
Safety Standards
IEC/EN61010-1:2001
IEC/EN61010-2-032:2002
EN/IEC 61010-031:2002+A1:2008
Safety Specifications
Category Rating: 1000 V CAT III, 600 V CAT IV, pollution
degree 2. The application of the Probe on uninsulated
conductors is limited to 1000 V ac rms or dc to ground and
frequencies below 1 kHz.
EMC Standards: IEC/EN 61326-1:2006
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and
workmanship for one year from the date of purchase. This
warranty does not cover fuses, disposable batteries, or
damage from accident, neglect, misuse, alteration,
contamination, or abnormal conditions of operation or handling.
Resellers are not authorized to extend any other warranty on
Fluke's behalf. To obtain service during the warranty period,
contact your nearest Fluke authorized service center to obtain
return authorization information, then send the product to that
Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR
PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM
ANY CAUSE OR THEORY. Since some states or countries do
not allow the exclusion or limitation of an implied warranty or of
incidental or consequential damages, this limitation of liability
may not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
11/99
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
3000/6000A-TF-4
Thin Flex AC Current Probes
Introduction
The 3000/6000A-TF-4 Thin Flex AC Current Probe sets (the
Probe or Product) have been designed for applications with
Fluke 1735 and Fluke 1740 series products for accurate non-
intrusive measurement of ac currents. Using the latest
technologies (integrated memory for calibration data) provides
current ranges from 0.8 A up to 6000 A in a frequency range of
40 Hz to 5 kHz.
Contacting Fluke
To contact Fluke, call one of the following telephone numbers:
Technical Support USA: 1-800-44-FLUKE
(1-800-443-5853)
Calibration/Repair USA: 1-888-99-FLUKE
(1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
Or, visit Fluke's website at www.fluke.com.
To register your product, visit http://register.fluke.com.
To view, print, or download the latest manual supplement, visit
http://us.fluke.com/usen/support/manuals.
Safety Instructions
Please read this section carefully. It will familiarize you with the
most important safety instructions for handling the Probe. In
this instruction sheet, a Warning identifies conditions and
actions that pose hazard(s) to the user. A Caution identifies
conditions and actions that may damage the Probe or the test
instruments.
PN 3986171
April 2011
2011 Fluke Corporation, All rights reserved. Specifications are subject to
change without notice. All product names are trademarks of their respective
companies.
Instruction Sheet

Advertisement

loading

Summary of Contents for Fluke 3000/6000A-TF-4

  • Page 1 To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE LIMITED WARRANTY AND LIMITATION OF LIABILITY (1-800-443-5853) This Fluke product will be free from defects in material and • Calibration/Repair USA: 1-888-99-FLUKE workmanship for one year from the date of purchase. This (1-888-993-5853)
  • Page 2 Do not dispose of this product as unsorted municipal  supplied by the Product can be compromised. waste. Go to Fluke’s website for recycling information. • High voltages and currents can be in adjacent circuits Do not apply to or remove from hazardous, live under test.