Setup

Setup

Pressure Relief Procedure

This sprayer builds up an internal
pressure of 2000 psi (138 bar, 13.8 MPa)
during use. Follow this Pressure Relief
Procedure whenever you stop spraying
and before cleaning, checking, servicing,
or transporting equipment to prevent
serious injury from pressurized fluid.
1.
Turn Prime Knob down to PRIME position
to relieve pressure.
10

Sprayer Setup

Use only water-based materials. Do not
use materials which state "FLAMMABLE"
on the packaging. For more information
about your material, request a Safety Data
Sheet (SDS) from distributor or retailer.
Keep spray area well-ventilated. Keep a
good supply of fresh air moving through
the area.
NOTE: Do NOT shake materials to be used
with this sprayer. Some fine finish lacquers
and enamels trap air when shaken, which
can affect sprayer performance. Stir the
material or check the manufacturer's
recommendation for the material being
sprayed.
1.
Insert one FlexLiner into the Cup
Support.
NOTE: Verify there is no damage to the top
sealing edge of the FlexLiner, such as a
crease or fold. If damaged it will leak air and
lose prime.