Kit Installation; Installation For Triton Ii Sand Filters - Pentair CLEARPRO TECHNOLOGY TR100 Installation And User Manual

Filter laterals extension kits
Table of Contents

Advertisement

2

KIT INSTALLATION

FILTER OPERATES UNDER HIGH PRESSURE.
When any part of the circulating system, (e.g., closure, pump, filter, valve(s), etc.), is serviced, air can enter the system and become
pressurized. Pressurized air can cause the top closure to separate which can result in severe injury, death, or property damage.
Filters should never be tested or subjected to air or gas under pressure. All gases are compressible and under pressure create a
danger. Severe bodily injury or property damage could occur if the filter is subjected to air or gas pressure.
Installing the ClearPro Technolgy
Only a qualified service professional should install
the ClearPro Technology filter extension kits.
Filters are designed and intended for use to filter
water. Refer to "Important Warning and Safety
Instructions" on pages ii - iii for additional
installation and safety information.
®
Triton
II Sand Filters
1. Use the closure wrench included with the filter, and
remove the top closure.
2. Remove sand (if there is sand in the filter).
3. Pivot diffuser away from the center of the tank by
rotating the diffuser assembly counter clockwise.
Note: Models TR100C, TR100C-3 and TR140C,
TR140C-3 have multi-diffuser assembly and do not
need to be removed to install new lateral kits.
4. Reach through the opening in the filter and remove
the old laterals. Turn counter clockwise to remove.
Note: Leave one of the laterals connected. Use this
to help loosen and unscrew the old hub.
5. Remove old hub from the filter.
6. Attach the new hub to the lower piping assembly.
7. Assemble the ten (10) new laterals into the hub.
Insert laterals with tabs vertical, then 1/4 turn to
align tabs horizontally to fit.
8. Put sand back into the filter.
Follow the sand specifications on page 4.
9. Check to make sure the tops on the diffusers are
parallel to the top of the sand bed.
10. Reattach the closure to filter.
11. After sand is ready, proceed to "Start Up
Instructions" on page 5.
CLEARPRO TECHNOLOGY
®
®
Filter Laterals Extension Kits
Filter Laterals Extension Kits Installation and User's Guide
IMPORTANT: Before servicing any part of the filter, be
sure the circulation system is OFF and pressure has
been relieved from the filter. If there is sand already in
the filter, open the air relief valve and drain the water
before removing closure or sand.
Remove filter closure with wrench
Pivot to move diffuser
Attach new laterals - Align tabs horizontally
Lateral
Tabs

Advertisement

Table of Contents
loading

Table of Contents