• VT100
• Term inal em ulat ion
• 115200 bps
• No parit y, 8 dat a bit s, 1 st op bit
• No flow cont rol
Connect t he m ale 9- pin end of t he console cable t o t he console port of t he Swit ch. Connect t he
fem ale end t o a serial port ( COM1, COM2 or ot her COM port ) of your com put er.
2.1.1.1 Default Ethernet Negotiation Settings
The fact ory default negot iat ion set t ings for t he Gigabit port s on t he Swit ch are:
• Speed: Aut o
• Duplex: Aut o
• Flow cont rol: Off
• Link Aggregat ion: Disabled
2.1.1.2 Auto-crossover
All port s are aut o- crossover, t hat is aut o- MDI X port s ( Media Dependent I nt erface Crossover) , so
you m ay use eit her a st raight- t hrough Et hernet cable or crossover Et hernet cable for all Gigabit port
connect ions. Aut o- crossover port s aut om at ically sense whet her t hey need t o funct ion as crossover
or st raight port s, so crossover cables can connect bot h com put ers and swit ches/ hubs.

2.1.2 Transceiver Slots

These are slot s for m ini- GBI C ( Gigabit I nt erface Convert er) t ransceivers or 100 Mbps Sm all Form -
fact or Pluggable ( SFP) t ransceivers. A t ransceiver is a single unit t hat houses a t ransm it t er and a
receiver. The Swit ch does not com e wit h t ransceivers. You m ust use t ransceivers t hat com ply wit h
t he SFP Transceiver Mult iSource Agreem ent ( MSA) . See t he SFF com m it t ee's I NF- 8074i
specificat ion Rev 1.0 for det ails.
You can change t ransceivers while t he Swit ch is operat ing. You can use different t ransceivers t o
connect t o Et hernet swit ches wit h different t ypes of fiber- opt ic or even copper cable connect ors.
To avoid possible eye injury, do not look into an operating fiber-optic
module's connectors.
• Type: SFP connect ion int erface
• Connect ion speed: 1 Gigabit per second ( Gbps) or 1 Megabit per second ( Mbps)
2.1.2.1 Transceiver Installation
Use t he following st eps t o inst all a m ini- GBI C t ransceiver ( SFP m odule) .
I nsert t he t ransceiver int o t he slot wit h t he exposed sect ion of PCB board facing down.
1
Press t he t ransceiver firm ly unt il it clicks int o place.