6-1-2.

LOCAL SETTING PROCEDURE

NOTE: Before performing the function setting, be sure to stop the operation of the air conditioner.
LOW NOISE MODE
LED lamp part
SW1
SW2
(1) Press the MODE switch button (SW1) for 3 seconds or more to switch to "Local setting mode".
(2) After confirming the LED lamp of POWER/MODE blinks 9 times, press the ENTER switch
button (SW3).
PUMP
POWER
LOW NOISE
ERROR
DOWN
MODE
(L1)
(L2)
Blinks
(9 times)
Sign "
" : Lights off
(3) Press the SELECT switch button (SW2), and adjust the LED lamp as shown below. Then the
LED lamp indicates the current setting.
LOW NOISE
(L2)
(L3)
LOW NOISE
Blink
MODE
(4) Press the ENTER switch button (SW3).
LOW NOISE
(L2)
LOW NOISE
MODE
Sign "
(5) Press the SELECT switch button (SW2), and adjust the LED lamps as shown below.
MODE 1
MODE 2
(6) Press the ENTER switch button (SW3) and fix it.
MODE 1
MODE 2
SW3
SW4
SW5
PEAK CUT
(L3)
(L4)
(L5)
(L6)
(L3)
" : Lights on
PEAK CUT
(L4)
(L5)
(L6)
Blink
Blink
PEAK CUT
(L4)
(L5)
(L6)
- (04-45) -