Pipe Size - Fujitsu AU G18LVLB Series Design & Technical Manual

1 phase type simultaneous multi system
Hide thumbs Also See for AU G18LVLB Series:
Table of Contents

Advertisement

1-3.

PIPE SIZE

PIPE SIZE SELECTION
Simultaneous multi system installation:
z
Twin type
L2
H2
L3
Main pipe
L1
diameter
(L1)
[mm (in.)]
H1
Branch pipe
diameter
(L2, L3)
[mm (in.)]
Piping length
[m (m)]
Main pipe
diameter
(L1)
[mm (in.)]
Branch pipe
diameter
(L2, L3)
[mm (in.)]
Piping length
[m (m)]
- (04-04) -
Model
Liquid pipes
Gas pipes
Liquid pipes
Gas pipes
Max. piping
length <L1+L2+L3>
(Pre-charge length)
Model
Liquid pipes
Gas pipes
Liquid pipes
Gas pipes
Max. piping
length <L1+L2+L3>
(Pre-charge length)
36 model
9.52 (3/8)
15.88
(5/8)
6.35 (1/4)
12.70 (1/2)
75
[30]
45 model / 54 model
9.52 (3/8)
15.88
(5/8)
9.52 (3/8)
15.88 (5/8)
75
[30]

Advertisement