Electrical Data

ELECTRIC SHOCK HAZARD
Turn off electric power before service or
installation.
All electrical connections and wiring MUST be
the National Electrical Code and all local codes
which have jurisdiction.
Failure to do so can result in personal injury or
death.
Circuit Rating/ Breaker/ power cord/ wall Receptacle
Model
KCS08A10, KCS10A10, KCS12A10
KCS14A10, KHS10A10, and
KCM14A10.
KCS12A30, KCS16A30,
KCM18A30, and KCM21A30.
KES12A33, KES16A33,
KHS12A33, KCL24A30, and
KCL28A30.
KEM18A34, KHL24A35,
KHM18A34A, KCL36A30,.
KEL24A35, and KEL36A35.
Wire Size - Use ONLY wiring size recommended by the National Electric Code (NEC) for single outlet branch
circuit.
Fuse/ Circuit Breaker - Use ONLY the correct HACR type and size fuse/circuit breaker. Read electrical ratings on
unit's rating plate. Proper circuit protection is the responsibiity of the homeowner.
Grounding - Unit MUST be grounded from branch circuit through service cord to unit, or through separate ground
wire provided on permanently connected units. Be sure that branch circuit or general purpose outlet is grounded.
Receptacle - The field supplied outlet must match plug on service cord and be within reach of service cord. Do
NOT alter the service cord or plug. Do NOT use an extension cord. Refer to the table above for proper receptacle
and fuse type.
13
SPECIFICATIONS
WARNING
Circuit Rating
Figure 206 (Circuit Breaker / Plug / Receptacle / Cord Rating)
electically unsafe conditions which could cause moderate
or serious property damage.
Read, understand and follow the above warning.
Breaker or
Plug Face
Power Cord
T-D Fuse
(NEMA#)
Length (ft.)
125V - 15A
5 - 15P
250V - 15A
6 - 15P
250V - 20A
6 - 20P
250V - 30A
6 - 30P
NOTICE
FIRE HAZARD
Required Wall
Receptacle
Wall Outlet
Appearance
NEMA NO.
6
5-15R
6
6-15R
6
6-20R
6
6-30R