REMOVE AND INSTALL THE CHASSIS
Install The Chassis
1. Carefully team lift the chassis and set it into the cabinet.
2. Slide the chassis stopping approximately 3" from full insertion.
3. Insert the chassis seal gasket (See Figure 503) one inch deep between the chassis and the cabinet A paint stir stick or ruler
might be helpful here. Begin inserting the gasket at either bottom corner and go up the side, across the top, and down the
opposite side. Then push the chassis all the way into the cabinet.
NOTE: If the chassis seal gasket is not installed or installed improperly,the operation of the unit will be negatively affected.
Operational noise and outside noise will also amplified.
4. Slide the chassis in the remaining three (3) inches.
5. Reattach the EntryGard™ chassis and EntryGard™ retainer wire..
42
Use Handle
Locations
(both sides)
CHASSIS SEAL GASKET
NOTE : WHEN INSTALLING THE CHASSIS
SEAL GASKET, BEGIN AT EITHER BOTTOM
CORNER AND GO UP THE SIDE & ACROSS
THE TOP & DOWN THE OPPOSITE SIDE.
Figure 503 (Chassis Installation)
CAUTION
Slide the chassis into the sleeve
stopping approximately 3" from full
insertion
Do not push, pull,
or lift from
center of support