Electrical Data - Friedrich Chill Premier Inverter Series Service Manual

R-32 refrigerant
Table of Contents

Advertisement

Electrical Data

ELECTRIC SHOCK HAZARD
Turn off electric power before service or
installation.
All electrical connections and wiring MUST be
codes which have jurisdiction.
Failure to do so can result in personal injury or
death.
Model
CCV08A10A
CCV10A10A
CCV12A10A
Wire Size - Use ONLY wiring size recommended for single outlet
branch circuit.
Fuse/ Circuit Breaker - Use ONLY the correct HACR type and size
fuse/circuit breaker. Read electrical ratings on unit's rating plate.
Proper circuit protection is the responsibiity of the homeowner.
Grounding - Unit MUST be grounded from branch circuit through
service cord to unit, or through separate ground wire provided on
permanently connected units. Be sure that branch circuit or general
purpose outlet is grounded.
Receptacle - The field supplied outlet must match plug on service cord
and be within reach of service cord. Do NOT alter the service cord
plug. Do NOT use an extension cord. Refer to the table above for
proper receptacle and fuse type.
Make sure the wiring is adequate for your unit.
All Wiring should meet all national and local codes and ordinances.
If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the
amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in Table 206.
DO NOT use an extension cord.
The cord provided will carry the proper amount of electrical power to the unit; an extension cord may not.
Make sure that the receptacle is compatible with the air conditioner cord plug provided.
Proper grounding must be maintained at all times. Two prong receptacles must be
replaced with a grounded receptacle by a certified electrician.
The grounded receptacle should meet all national and local codes and ordinances. You must use the three prong plug
furnished with the air conditioner. Under no circumstances should you remove the ground prong from the plug.
10
SPECIFICATIONS
WARNING
Circuit Rating
Breaker or T-D Fuse
125V-15A
Figure 204 (Circuit Breaker / Plug / Receptacle / Cord Rating)
electically unsafe conditions which could cause moderate
or serious property damage.
Read, understand and follow the above warning.
Plug Face
Power Cord
(NEMA#)
Length (ft.)
5-15P
Electrical Shock Hazard
Make sure your electrical receptacle
has the same configuration as your air
conditioner's plug. If different, consult a
Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.Always
plug into a grounded 3 prong outlet.
Failure to follow these instructions can
result in death, fire, or electrical shock.
NOTICE
FIRE HAZARD
Wall Outlet
Appearance
5
WARNING
or