Standard installation

NO RECESS
NON-COMBUSTIBLE FACING
DRL36
DRL48
DRL60
16"
130°
150°
140°
12"
140°
160°
155°
8"
160°
170°
175°
4"
175°
180°
200°
Surface temperatures are
based on a 3 hour burn time
IMPORTANT
Temperatures are based off of
the minimum enclosure size.
Combustible header
DRL60 fireplaces come with both a
steel stud and a combustible stud
heat deflector. The steel stud exists as
a support for the cement board.
Cement board
WARNING
Combustible facing material not allowed with standard minimum
10
Enclosure top
No materials
other than
venting
components
are permitted
in this area
Venting
ports
closed
chase
TV over fireplace installation
WORKS FOR TV PLACEMENT ON CHASE
NON-COMBUSTIBLE FACING
Combustible header
DRL60 fireplaces come with both a
steel stud and a combustible stud
heat deflector. The steel stud exists as
a support for the cement board.
IMPORTANT
Temperatures are based off of
the minimum enclosure size.
Installation
Enclosure top
DRL3613, DRL4813
45" MIN. CHASE
DRL6013
60" MIN. CHASE